Immediate vs early loading of 6.6 mm flapless-placed single implants: 9 years after-loading report of a split-mouth randomised controlled trial.

Gioacchino Cannizzaro, Pietro Felice, Anna Trullenque-Eriksson, Matteo Lazzarini, Eugenio Velasco-Ortega, Marco Esposito.   

Abstract

PURPOSE: To evaluate the long-term effectiveness of 6.6 mm long flapless-placed single implants loaded immediately or early loaded at 6 weeks.
MATERIALS AND METHODS: Thirty patients each received two single Nanotite External Hex Biomet 3i implants, which were then randomly allocated to be either immediately or early loaded, according to a split-mouth design. Implants had to be inserted with a torque superior to 40 Ncm. Provisional crowns were put in slight occlusal contact and replaced by definitive crowns 3 months after loading. Patients were followed for 9 years after loading. Outcome measures were implant failures, biological and biomechanical complications, peri-implant marginal bone level changes and patient preference.
RESULTS: A total of 29 implants were immediately loaded, while 31 were early loaded. Nine years after loading, three patients dropped out. One implant failed in each group within 2 months after loading. One patient asked for the immediately loaded crown to be remade for aesthetic reasons and then again to have both metal-ceramic crowns replaced by full ceramic crowns. Another patient had his immediately loaded crown remade after repeated debonding. Six patients from each group experienced complications, the difference being not statistically significant (difference of proportions = 0.00; 95% CI -0.20 to 0.20, P = 1.000). Peri-implant bone loss was 0.60 mm for patients with immediately loaded implants and 0.46 mm for early loaded ones, which was not significantly different (mean difference = 0.14 mm, 95% CI -0.13 to 0.41, P = 0.283). All but one patient had no preference for either procedure after 9 years.
CONCLUSIONS: Flapless-placed 6.6 mm long single implants can be immediately loaded and remain successful up to 9 years after loading. Conflict-of-interest statement:

Entities:  

Mesh:

Year:  2018        PMID: 29806664

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  4 in total

1.  Gingival recession behavior with immediate implant placement in the anterior maxilla with buccal dehiscence without additional augmentation-a pilot study.

Authors:  Veronika Pohl; Lukas Fürhauser; Robert Haas; Sebastian Pohl
Journal:  Clin Oral Investig       Date:  2020-01-08       Impact factor: 3.573

Review 2.  A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns.

Authors:  Bjarni Elvar Pjetursson; Irena Sailer; Andrey Latyshev; Kerstin Rabel; Ralf-Joachim Kohal; Duygu Karasan
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

3.  Immediate loading of short implants: A systematic review.

Authors:  Mahdi Hadilou; Pooya Ebrahimi; Behnaz Karimzadeh; Ashkan Ghaffary; Leila Gholami; Zahra Fathifar
Journal:  J Adv Periodontol Implant Dent       Date:  2021-03-06

Review 4.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.