Measuring the impact of cushion design on buttocks tissue deformation: An MRI approach.

Sharon E Sonenblum1, Jason Ma, Stephen H Sprigle2, Thomas R Hetzel3, John McKay Cathcart4.   

Abstract

AIM: To establish a research approach for describing how different wheelchair cushion designs impact buttocks tissue deformation during sitting.
MATERIALS AND METHODS: The buttocks of 4 individuals with spinal cord injury and significant atrophy were scanned sitting in a FONAR Upright MRI. Scans were collected with the individuals' buttocks fully suspended without pelvic support, and seated on 3 different commercially available wheelchair cushions. Multi-planar scans were analyzed to provide 3D renderings and measurements of tissue thickness and shape.
RESULTS: Bulk tissue thicknesses at the ischium, which rarely included muscle, were reduced by more than 60% on enveloping cushion designs studied (i.e., Roho HP and Matrx Vi), and more variably (23-60%) on an orthotic off-loading design (i.e., Java). Adipose was typically displaced posterior and superior from the unloaded condition, with more lateral displacement on the Roho HP and Matrx Vi and more medial displacement present on the Java. Large changes in angle at the sacro-coccygeal joint indicated significant loading on the region. Deformation at the greater trochanter was more consistent across surfaces. Greater interface pressures tended to be associated with greater deformation, but the relationship varied by individuals and was highly non-linear.
CONCLUSIONS: The buttocks in this study all deformed significantly, but at different locations and in different manners across all 3 surfaces. Attention needs to be paid to the regions of greatest deformation. A future metric of shape compliance should consider cushion performance at all high risk regions, and changes to the amount and shape of tissue in the regions of interest.
Copyright © 2018 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Buttocks; MRI; Multi-planar; Pressure ulcer; Tissue deformation; Wheelchair cushion

Mesh:

Year:  2018        PMID: 29804800     DOI: 10.1016/j.jtv.2018.04.001

Source DB:  PubMed          Journal:  J Tissue Viability        ISSN: 0965-206X            Impact factor:   2.932


  3 in total

Review 1.  A Primary Care Provider's Guide to Wheelchair Prescription for Persons With Spinal Cord Injury.

Authors:  Erin Michael; Terin Sytsma; Rachel E Cowan
Journal:  Top Spinal Cord Inj Rehabil       Date:  2020

2.  Subcutaneous Fat Thickness Remarkably Influences Contact Pressure and Load Distribution of Buttock in Seated Posture.

Authors:  Kuan Wang; Yufang Chen; Shangjun Huang; Lejun Wang; Wenxin Niu
Journal:  J Healthc Eng       Date:  2021-11-30       Impact factor: 2.682

3.  Changes in external ischial tuberosity width at varying trunk-thigh angles between sexes using two measurement methods.

Authors:  Yi-Lang Chen
Journal:  Sci Rep       Date:  2021-10-04       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.