Literature DB >> 29804739

Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

Elisabeth Vukovic1, Martin Czerny1, Friedhelm Beyersdorf1, Martin Wolkewitz2, Mikolaj Berezowski1, Matthias Siepe1, Philipp Blanke3, Bartosz Rylski4.   

Abstract

OBJECTIVE: The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft.
METHODS: Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years).
RESULTS: The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively.
CONCLUSIONS: The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation.
Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Abdominal aortic aneurysm; Anaconda AAA Stent Graft System; Endoleak; Endovascular; Migration

Mesh:

Year:  2018        PMID: 29804739     DOI: 10.1016/j.jvs.2018.02.041

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  1 in total

1.  Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair.

Authors:  Maaike A Koenrades; Marianne R F Bosscher; Jouke T Ubbink; Cornelis H Slump; Robert H Geelkerken
Journal:  J Endovasc Ther       Date:  2019-12       Impact factor: 3.487

  1 in total