Ni-Hong Pang1, Qian Liu1, Xiang-Ran Lu1, Su-Fen Yang1, Dong-Dong Lin1, Guo-Xin Hu2.
Abstract
Enasidenib, an oral product for treating Acute Myeloid Leukemia, has been approved by FDA in Aug, 2017. In this study, we set up an ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for measuring Enasidenib and imatinib (internal standard, IS), simultaneously. Enasidenib and imatinib were separated on an ACQUITY UPLC BEH C18 Column (2.1 mm × 50 mm, 1.7 μm, 132 Å). Mass detection was carried out by electrospray ionization in the position mode, and the multiple reaction monitoring transitions were m/z 474.23 → 456.17 and m/z 494.30 → 394.20 for Enasidenib and imatinib, respectively. Linearity (2 - 500 ng·mL-1, R2 > 0.999), precision and accuracy (RE < ± 15%), extraction recovery (≥ 96.69%), matrix effect (≥ 96.47%) and stability (RE < ± 10%) were validated which demonstrated the robustness of our method. This rapid, efficient and reliable UPLC-MS/MS method shows specificity and repeatability of Enasidenib in rat plasma and can be used in further pharmacokinetic studies.Entities:
Keywords: Enasidenib; Pharmacokinetic study; Rat plasma; UPLC-MS/MS
Mesh:
Substances:
Year: 2018 PMID: 29803908 DOI: 10.1016/j.jpba.2018.04.039
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935