Literature DB >> 29801221

Determination of hexavalent Cr in river sediments by speciated isotope dilution inductively coupled plasma mass spectrometry.

Ana Drinčić1, Tea Zuliani1, Janez Ščančar1, Radmila Milačič2.   

Abstract

During a sampling campaign in September 2015, elevated chromium (Cr) concentrations were observed in sediments of industrially exposed sites of the Sava River (stainless steel production and impact of metallurgic industry). To verify if sediments also contained hazardous hexavalent Cr (Cr(VI)), there was a need to develop a sensitive and reliable analytical procedure for its determination. In the determination of Cr(VI) in environmental samples, it is necessary to evaluate the suitability of the applied analytical methodology for each individual sample matrix. In these studies, the use of isotopically enriched Cr tracers importantly contribute to the validity of the obtained results. In the present work, an analytical procedure was optimised for the extraction of total Cr(VI) from sediments and the content of Cr(VI) determined by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). To leach the total amount of Cr(VI) from sediments, an ultrasound-assisted extraction procedure was applied at 80 °C, using 2% NaOH + 3% Na2CO3 as the extraction solution. The addition of 0.4 mol L-1 MgCl2 prevented oxidation of Cr(III) during the extraction step. To control for species interconversion and for an accurate calculation of Cr(VI) concentration by speciated isotope dilution (ID)-ICP-MS, the alkaline extract was doubly spiked with enriched 50Cr(VI) and 53Cr(III). The accuracy of the determination of Cr(VI) was verified by analysing the certified reference material CRM 041 (Cr(VI) in soil), and by spike recovery test. Low limits of detection (LOD) and quantification (LOQ) (1.25 and 4.0 μg Cr(VI) kg-1, respectively) and good repeatability of measurement (relative standard deviation better than ±4.8%) were obtained. The analytical data revealed that Cr(VI) concentrations in sediments of the Sava River did not represent any known environmental hazard.
Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alkaline extraction; Cr(VI); Sediments; Speciated isotope dilution inductively coupled plasma mass spectrometry; The Sava River

Mesh:

Substances:

Year:  2018        PMID: 29801221     DOI: 10.1016/j.scitotenv.2018.05.112

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  1 in total

1.  A highly sensitive and selective on-off fluorescent sensor based on a complex of polySchiff-Fe2+ for Cr(vi) detection in an aqueous medium.

Authors:  Zhiying Li; Congshu Li; Huiyun Yan
Journal:  RSC Adv       Date:  2021-03-01       Impact factor: 3.361

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.