Literature DB >> 29801163

Biomechanical Robustness of a Contemporary Cementless Stem to Surgical Variation in Stem Size and Position.

Rami M A Al-Dirini1, Dermot O'Rourke2, Daniel Huff3, Saulo Martelli2, Mark Taylor1.   

Abstract

Successful designs of total hip replacement (THR) need to be robust to surgical variation in sizing and positioning of the femoral stem. This study presents an automated method for comprehensive evaluation of the potential impact of surgical variability in sizing and positioning on the primary stability of a contemporary cementless femoral stem (Corail®, DePuy Synthes). A patient-specific finite element (FE) model of a femur was generated from computed tomography (CT) images from a female donor. An automated algorithm was developed to span the plausible surgical envelope of implant positions constrained by the inner cortical boundary. The analysis was performed on four stem sizes: oversized, ideal (nominal) sized, and undersized by up to two stem sizes. For each size, Latin hypercube sampling was used to generate models for 100 unique alignment scenarios. For each scenario, peak hip contact and muscle forces published for stair climbing were scaled to the donor's body weight and applied to the model. The risk of implant loosening was assessed by comparing the bone-implant micromotion/strains to thresholds (150 μm and 7000 με) above which fibrous tissue is expected to prevail and the periprosthetic bone to yield, respectively. The risk of long-term loosening due to adverse bone resorption was assessed using bone adaptation theory. The range of implant positions generated effectively spanned the available intracortical space. The Corail stem was found stable and robust to changes in size and position, with the majority of the bone-implant interface undergoing micromotion and interfacial strains that are well below 150 μm and 7000 με, respectively. Nevertheless, the range of implant positions generated caused an increase of up to 50% in peak micromotion and up to 25% in interfacial strains, particularly for retroverted stems placed in a medial position.

Entities:  

Mesh:

Year:  2018        PMID: 29801163     DOI: 10.1115/1.4039824

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  2 in total

1.  The direct anterior approach provokes varus stem alignment when using a collarless straight tapered stem.

Authors:  Marcel Haversath; Martin Lichetzki; Sebastian Serong; André Busch; Stefan Landgraeber; Marcus Jäger; Tjark Tassemeier
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-30       Impact factor: 3.067

2.  Topology Optimisation for Compliant Hip Implant Design and Reduced Strain Shielding.

Authors:  Nathanael Tan; Richard J van Arkel
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.