Literature DB >> 29797038

Metrology for stable isotope reference materials: 13C/12C and 18O/16O isotope ratio value assignment of pure carbon dioxide gas samples on the Vienna PeeDee Belemnite-CO2 scale using dual-inlet mass spectrometry.

Abneesh Srivastava1, R Michael Verkouteren2.   

Abstract

Isotope ratio measurements have been conducted on a series of isotopically distinct pure CO2 gas samples using the technique of dual-inlet isotope ratio mass spectrometry (DI-IRMS). The influence of instrumental parameters, data normalization schemes on the metrological traceability and uncertainty of the sample isotope composition have been characterized. Traceability to the Vienna PeeDee Belemnite(VPDB)-CO2 scale was realized using the pure CO2 isotope reference materials(IRMs) 8562, 8563, and 8564. The uncertainty analyses include contributions associated with the values of iRMs and the repeatability and reproducibility of our measurements. Our DI-IRMS measurement system is demonstrated to have high long-term stability, approaching a precision of 0.001 parts-per-thousand for the 45/44 and 46/44 ion signal ratios. The single- and two-point normalization bias for the iRMs were found to be within their published standard uncertainty values. The values of 13C/12C and 18O/16O isotope ratios are expressed relative to VPDB-CO2 using the [Formula: see text] and [Formula: see text] notation, respectively, in parts-per-thousand (‰ or per mil). For the samples, value assignments between (-25 to +2) ‰ and (-33 to -1) ‰ with nominal combined standard uncertainties of (0.05, 0.3) ‰ for [Formula: see text] and [Formula: see text], respectively were obtained. These samples are used as laboratory reference to provide anchor points for value assignment of isotope ratios (with VPDB traceability) to pure CO2 samples. Additionally, they serve as potential parent isotopic source material required for the development of gravimetric based iRMs of CO2 in CO2-free dry air in high pressure gas cylinder packages at desired abundance levels and isotopic composition values. Graphical abstract CO2 gas isotope ratio metrology.

Entities:  

Keywords:  DI-IRMS; Isotope metrology; Isotope reference material; SI traceability; VPDB-CO2 traceability; δ 13C

Year:  2018        PMID: 29797038      PMCID: PMC6082370          DOI: 10.1007/s00216-018-1064-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  13 in total

1.  Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry.

Authors:  D A Merritt; J M Hayes
Journal:  Anal Chem       Date:  1994-07-15       Impact factor: 6.986

2.  web-based interactive data processing: application to stable isotope metrology.

Authors:  R M Verkouteren; J N Lee
Journal:  Fresenius J Anal Chem       Date:  2001-08

3.  High-precision, automated stable isotope analysis of atmospheric methane and carbon dioxide using continuous-flow isotope-ratio mass spectrometry.

Authors:  Rebecca Fisher; David Lowry; Owen Wilkin; Srimathy Sriskantharajah; Euan G Nisbet
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

4.  Automated simultaneous measurement of the δ(13) C and δ(2) H values of methane and the δ(13) C and δ(18) O values of carbon dioxide in flask air samples using a new multi cryo-trap/gas chromatography/isotope ratio mass spectrometry system.

Authors:  Willi A Brand; Michael Rothe; Peter Sperlich; Martin Strube; Magnus Wendeberg
Journal:  Rapid Commun Mass Spectrom       Date:  2016-07-15       Impact factor: 2.419

5.  Extraction of CO2 from air samples for isotopic analysis and limits to ultra high precision delta18O determination in CO2 gas.

Authors:  R A Werner; M Rothe; W A Brand
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

6.  New guidelines for delta13C measurements.

Authors:  Tyler B Coplen; Willi A Brand; Matthias Gehre; Manfred Gröning; Harro A J Meijer; Blaza Toman; R Michael Verkouteren
Journal:  Anal Chem       Date:  2006-04-01       Impact factor: 6.986

7.  Calibration strategies for the determination of stable carbon absolute isotope ratios in a glycine candidate reference material by elemental analyser-isotope ratio mass spectrometry.

Authors:  Philip J H Dunn; Dmitry Malinovsky; Heidi Goenaga-Infante
Journal:  Anal Bioanal Chem       Date:  2014-06-08       Impact factor: 4.142

8.  Development of a Northern Continental Air Standard Reference Material.

Authors:  George C Rhoderick; Duane R Kitzis; Michael E Kelley; Walter R Miller; Bradley D Hall; Edward J Dlugokencky; Pieter P Tans; Antonio Possolo; Jennifer Carney
Journal:  Anal Chem       Date:  2016-03-01       Impact factor: 6.986

9.  Methods and limitations of 'clumped' CO2 isotope (Delta47) analysis by gas-source isotope ratio mass spectrometry.

Authors:  K W Huntington; J M Eiler; H P Affek; W Guo; M Bonifacie; L Y Yeung; N Thiagarajan; B Passey; A Tripati; M Daëron; R Came
Journal:  J Mass Spectrom       Date:  2009-09       Impact factor: 1.982

10.  A system for high-quality CO2 isotope analyses of air samples collected by the CARIBIC Airbus A340-600.

Authors:  S Assonov; P Taylor; C A M Brenninkmeijer
Journal:  Rapid Commun Mass Spectrom       Date:  2009-05       Impact factor: 2.419

View more
  1 in total

1.  Physical model for multi-point normalization of dual-inlet isotope ratio mass spectrometry data.

Authors:  Abneesh Srivastava
Journal:  Anal Bioanal Chem       Date:  2022-06-01       Impact factor: 4.478

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.