Analysis of Pulse Signals Based on Array Pulse Volume.

Ji Cui1, Li-Ping Tu2, Jian-Feng Zhang1, Shao-Liang Zhang1, Zhi-Feng Zhang1, Jia-Tuo Xu3.   

Abstract

OBJECTIVE: To collect and analyze multi-dimensional pulse diagram features with the array sensor of a pressure profile system (PPS) and study the characteristic parameters of the new multi-dimensional pulse diagram by pulse diagram analysis technology.
METHODS: The pulse signals at the Guan position of left wrist were acquired from 105 volunteers at the Shanghai University of Traditional Chinese Medicine. We obtained the pulse data using an array sensor with 3×4 channels. Three dimensional pulse diagrams were constructed for the validated pulse data, and the array pulse volume (APV) parameter was computed by a linear interpolation algorithm. The APV differences among normal pulse (NP), wiry pulse (WP) and slippery pulse (SP) were analyzed using one-way analysis of variance. The coefficients of variation (CV) were calculated for WP, SP and NP.
RESULTS: The APV difference between WP and NP in the 105 volunteers was statistically significant (6.26±0.28 vs. 6.04±0.36, P=0.048), as well as the difference between WP and SP (6.26±0.28 vs. 6.07±0.46, P=0.049). However, no statistically significant difference was found between NP and SP (P=0.75). WP showed a similar CV (4.47%) to those of NP (5.96%) and SP (7.58%).
CONCLUSION: The new parameter APV could differentiate between NP or SP and WP. Accordingly, APV could be considered an useful parameter for the analysis of array pulse diagrams in Chinese medicine.

Entities:  

Keywords:  Chinese medicine; array pulse volume; pulse sensor; pulse signal

Mesh:

Year:  2018        PMID: 29790062     DOI: 10.1007/s11655-018-2776-y

Source DB:  PubMed          Journal:  Chin J Integr Med        ISSN: 1672-0415            Impact factor:   1.978


  6 in total

1.  [The editorial and prospective of Chinese medicine health evaluation systems studies based on four diagnostic information and decision support].

Authors:  Jia-Tuo Xu
Journal:  Zhongguo Zhong Xi Yi Jie He Za Zhi       Date:  2012-03

2.  The correlation between pulse diagnosis and constitution identification in traditional Chinese medicine.

Authors:  Han-Kuei Wu; Yu-Shien Ko; Yu-Sheng Lin; Hau-Tieng Wu; Tung-Hu Tsai; Hen-Hong Chang
Journal:  Complement Ther Med       Date:  2016-12-21       Impact factor: 2.446

3.  How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosis.

Authors:  Yu-Feng Chung; Chung-Shing Hu; Cheng-Chang Yeh; Ching-Hsing Luo
Journal:  Comput Biol Med       Date:  2013-02-04       Impact factor: 4.589

4.  A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres.

Authors:  Changhyun Pang; Gil-Yong Lee; Tae-il Kim; Sang Moon Kim; Hong Nam Kim; Sung-Hoon Ahn; Kahp-Yang Suh
Journal:  Nat Mater       Date:  2012-09       Impact factor: 43.841

5.  Stringlike pulse quantification study by pulse wave in 3D pulse mapping.

Authors:  Ching-Hsing Luo; Yu-Feng Chung; Cheng-Chang Yeh; Xiao-Chen Si; Chien-Chen Chang; Chung-Shing Hu; Yu-Wen Chu
Journal:  J Altern Complement Med       Date:  2012-10       Impact factor: 2.579

6.  Silk-molded flexible, ultrasensitive, and highly stable electronic skin for monitoring human physiological signals.

Authors:  Xuewen Wang; Yang Gu; Zuoping Xiong; Zheng Cui; Ting Zhang
Journal:  Adv Mater       Date:  2013-12-17       Impact factor: 30.849

  6 in total
  3 in total

1.  Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders.

Authors:  Zi-Juan Bi; Xing-Hua Yao; Xiao-Juan Hu; Pei Yuan; Xiao-Jing Guo; Zhi-Ling Guo; Si-Han Wang; Jun Li; Yu-Lin Shi; Jia-Cai Li; Ji Cui; Jia-Tuo Xu
Journal:  Evid Based Complement Alternat Med       Date:  2022-02-17       Impact factor: 2.629

Review 2.  The Research and Development Thinking on the Status of Artificial Intelligence in Traditional Chinese Medicine.

Authors:  Nan Li; Jiarui Yu; Xiaobo Mao; Yuping Zhao; Luqi Huang
Journal:  Evid Based Complement Alternat Med       Date:  2022-05-02       Impact factor: 2.650

3.  Fourier Series Analysis for Novel Spatiotemporal Pulse Waves: Normal, Taut, and Slippery Pulse Images.

Authors:  Bo Peng; Ching-Hsing Luo; Nilotpal Sinha; Cheng-Chi Tai; Xiaohua Xie; Haiqing Xie
Journal:  Evid Based Complement Alternat Med       Date:  2019-11-27       Impact factor: 2.629