Literature DB >> 29787488

Effects of Scleral-lens Tear Clearance on Corneal Edema and Post-lens Tear Dynamics: A Pilot Study.

Bo Tan1, Yixiu Zhou1, Tiffany L Yuen1, Kristina Lin1, Langis Michaud2, Meng C Lin1.   

Abstract

SIGNIFICANCE: The present study with small-diameter scleral lenses (SLs) revealed that post-lens tear thickness (PoLTT) was significantly associated with post-lens tear mixing, but not with central corneal edema, after short-term SL wear.
PURPOSE: The aim of this study was to investigate the influence of SL tear clearance (PoLTT) on central corneal thickness and post-lens tear dynamics during 5-hour lens wear.
METHODS: Neophytes with no active ocular disease were fitted bilaterally with SLs (hofocon A; 15.6-mm diameter; ~438-μm thickness; 97 Dk; 1.44 refractive index) with various initial PoLTT values ranging from 74 to 543 μm. Central corneal thickness and PoLTT were measured using optical coherence tomography during lens wear. Tear mixing was assessed using fluorogram and "out-in" method.
RESULTS: The mean central corneal edema after 5-hour lens wear was 1.51% (95% confidence interval, 1.26 to 1.76%; P < .001), reached its peak at 2-hour post-lens insertion (1.65% [95% confidence interval, 1.45 to 1.85%]), and was independent of PoLTT. The fastest fluorescence decay of the post-lens tear film was observed superiorly. The fluorescence decay rate increased from center to periphery in all quadrants except superiorly. An inverse relationship was found between PoLTT and fluorescence decay rate at both 20-minute and 5-hour wear after lens insertion (P < .05). Excluding observations with out-in time exceeding 5 minutes, we found a direct relationship between PoLTT at 20 minutes after lens insertion and out-in time (P = .047). The % change in the PoLTT after 5-hour wear was greater with a thinner initial tear clearance than those with a thicker one (P = .034).
CONCLUSIONS: Within our study parameters, a thinner PoLTT under a small-diameter SL was associated with faster PoLTT mixing. However, there was no relationship between PoLTT and central corneal thickness during 5-hour SL wear.

Entities:  

Mesh:

Year:  2018        PMID: 29787488     DOI: 10.1097/OPX.0000000000001220

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  3 in total

1.  Corneal tissue properties following scleral lens wear using Scheimpflug imaging.

Authors:  Alejandra Consejo; David Alonso-Caneiro; Maciej Wojtkowski; Stephen J Vincent
Journal:  Ophthalmic Physiol Opt       Date:  2020-07-23       Impact factor: 3.117

Review 2.  How Can We Best Measure the Performance of Scleral Lenses? Current Insights.

Authors:  Rute J Macedo-de-Araújo; Daddi Fadel; Melissa Barnett
Journal:  Clin Optom (Auckl)       Date:  2022-04-07

3.  Limbal Metabolic Support Reduces Peripheral Corneal Edema with Contact-Lens Wear.

Authors:  Young Hyun Kim; Meng C Lin; Clayton J Radke
Journal:  Transl Vis Sci Technol       Date:  2020-06-30       Impact factor: 3.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.