Literature DB >> 29781608

Characterization of the Ionic Liquid/Electrode Interfacial Relaxation Processes Under Potential Polarization for Ionic Liquid Amperometric Gas Sensor Method Development.

Lu Lin, Peng Zhao, Andrew J Mason1, Xiangqun Zeng.   

Abstract

Electrochemical amperometric sensors require a constant or varying potential at the working electrode that drives redox reactions of the analyte for detection. The interfacial redox reaction(s) can result in the formation of new chemical products that could change the initial condition of the electrode/electrolyte interface. If the products are not inert and/or cannot be removed from the system such that the initial condition of the electrode/electrolyte interface cannot be restored, the sensor signal baseline would consequently drift, which is problematic for the continuous and real-time sensors. By setting the electrode potential with the periodical ON-OFF mode, electrolysis can be forestalled during the off mode which can minimize the sensor signal baseline drift and reduce the power consumption of the sensor. However, it is known that the relaxation of the structure in the electrical double layer at the ionic liquid/electrode interface to the steps of the electrode potential is slow. This work characterized the electrode/electrolyte interfacial relaxation process of an ionic liquid based electrochemical gas (IL-EG) sensor by performing multiple potential step experiments in which the potential is stepped from an open circuit potential (OCP) to the amperometric sensing potential at various frequencies with different time periods. Our results showed that by shortening the sensing period as well as extending the idle period (i.e., enlarge the ratio of idle period versus sensing period) of the potential step experiments, the electrode/electrolyte interface is prone to relax to its original state, and thus reduces the baseline drift. Additionally, the high viscosity of the ionic liquids is beneficial for electrochemical regeneration via the implementation of a conditioning step at zero volts at the electrode/electrolyte. By setting the working electrode at zero volts instead of OCP, our results showed that it could further minimize the baseline drift, enhance the sensing signal stability, and extend the functioning lifetime of a continuous IL-EG oxygen sensor.

Entities:  

Keywords:  amperometric sensor; electric double layer; interfacial relaxation; ionic liquids; oxygen sensor

Mesh:

Substances:

Year:  2018        PMID: 29781608      PMCID: PMC7192316          DOI: 10.1021/acssensors.8b00155

Source DB:  PubMed          Journal:  ACS Sens        ISSN: 2379-3694            Impact factor:   7.711


  26 in total

1.  Atmospheric solids analysis probe mass spectrometry: a new approach for airborne particle analysis.

Authors:  Emily A Bruns; Véronique Perraud; John Greaves; Barbara J Finlayson-Pitts
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

2.  Use of X-ray absorption spectroscopy to speciate manganese in airborne particulate matter from five counties across the United States.

Authors:  Saugata Datta; Ana M Rule; Jana N Mihalic; Steve N Chillrud; Benjamin C Bostick; Juan P Ramos-Bonilla; Inkyu Han; Lisa M Polyak; Alison S Geyh; Patrick N Breysse
Journal:  Environ Sci Technol       Date:  2012-03-01       Impact factor: 9.028

3.  Review of electrochemical hydrogen sensors.

Authors:  Ghenadii Korotcenkov; Sang Do Han; Joseph R Stetter
Journal:  Chem Rev       Date:  2009-03-11       Impact factor: 60.622

4.  Ultraslow relaxation of the structure at the ionic liquid|gold electrode interface to a potential step probed by electrochemical surface plasmon resonance measurements: asymmetry of the relaxation time to the potential-step direction.

Authors:  Naoya Nishi; Yuta Hirano; Toshiyuki Motokawa; Takashi Kakiuchi
Journal:  Phys Chem Chem Phys       Date:  2013-06-12       Impact factor: 3.676

Review 5.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

6.  Toward continuous amperometric gas sensing in ionic liquids: rationalization of signal drift nature and calibration methods.

Authors:  Lu Lin; Xiangqun Zeng
Journal:  Anal Bioanal Chem       Date:  2018-06-13       Impact factor: 4.142

7.  Interfacial ionic 'liquids': connecting static and dynamic structures.

Authors:  Ahmet Uysal; Hua Zhou; Guang Feng; Sang Soo Lee; Song Li; Peter T Cummings; Pasquale F Fulvio; Sheng Dai; John K McDonough; Yury Gogotsi; Paul Fenter
Journal:  J Phys Condens Matter       Date:  2014-12-05       Impact factor: 2.333

8.  Surface structure at the ionic liquid-electrified metal interface.

Authors:  Steven Baldelli
Journal:  Acc Chem Res       Date:  2008-01-31       Impact factor: 22.384

9.  Highly Sensitive Capacitive Gas Sensing at Ionic Liquid-Electrode Interfaces.

Authors:  Zhe Wang; Min Guo; Xiaoyi Mu; Soumyo Sen; Thomas Insley; Andrew J Mason; Petr Král; Xiangqun Zeng
Journal:  Anal Chem       Date:  2016-01-12       Impact factor: 6.986

10.  Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

Authors:  Nicholas E Pingitore; Juan W Clague; Maria A Amaya; Beata Maciejewska; Jesús J Reynoso
Journal:  PLoS One       Date:  2009-04-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.