Literature DB >> 29778827

Intra- and inter-reliability of fleximetry in individuals with chronic shoulder pain.

Iran Henrique da Silva1, José Mariedson da Silva Junior1, Aldair Darlan Santos-de-Araújo1, Cid André Fidelis de Paula Gomes2, Cesário da Silva Souza1, Priscila Helena Vanin Alves de Souza Matias1, Almir Vieira Dibai-Filho3.   

Abstract

OBJECTIVE: To evaluate the intra- and inter-rater reliability of fleximetry in the measurement of range of motion (ROM) in individuals with chronic shoulder pain.
DESIGN: Reliability study.
SETTING: Physiotherapy clinic. PARTICIPANTS: Thirty individuals of both genders, ages between 18 and 45 years, with chronic shoulder pain. MAIN OUTCOME MEASURES: Fleximetry was used to measurement shoulder ROM (flexion, hyperextension, abduction, medial and lateral rotation, and horizontal abduction and adduction). Two examiners performed the evaluations of the shoulder ROM at two time points (interval of one week between them).
RESULTS: In the intra-rater reliability, substantial to excellent reliability was found, with intraclass correlation coefficient (ICC) values ranging from 0.79 to 0.92, standard error of the measurement (SEM) values ranging from 5.70 to 8.72°, and minimum detectable change (MDC) values varying between 15.80 and 25.18°. Regarding the inter-rater reliability, moderate to excellent reliability was observed, with ICC values ranging from 0.68 to 0.96, SEM values ranging from 4.98 to 11.53°, and MDC values ranging from 13.82 to 31.97°.
CONCLUSION: The use of the fleximeter to measure shoulder ROM presents acceptable reliability values in individuals with chronic shoulder pain, which supports the use of this method of evaluation in research and clinical practice.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chronic pain; Reproducibility of results; Shoulder impingement syndrome; Shoulder joint

Mesh:

Year:  2018        PMID: 29778827     DOI: 10.1016/j.ptsp.2018.05.011

Source DB:  PubMed          Journal:  Phys Ther Sport        ISSN: 1466-853X            Impact factor:   2.365


  3 in total

1.  Seated Single-Arm Shot-Put Test to Measure the Functional Performance of the Upper Limbs in Exercise Practitioners With Chronic Shoulder Pain: A Reliability Study.

Authors:  Jocassia Silva Pinheiro; Otávio Lima Soares Monteiro; Cezar Augusto Brito Pinheiro; Luana Maria Brenha Penha; Mariana Quixabeira Guimarães Almeida; Daniela Bassi-Dibai; Flavio de Oliveira Pires; Christian Emmanuel Torres Cabido; Cid André Fidelis-de-Paula-Gomes; Almir Vieira Dibai-Filho
Journal:  J Chiropr Med       Date:  2020-09-04

2.  Construct validity and reliability of the 2-minute step test in patients with knee osteoarthritis.

Authors:  Thiago Felipe de Morais Almeida; Almir Vieira Dibai-Filho; Fernanda de Freitas Thomaz; Eloiza Adelaide Amaral Lima; Christian Emmanuel Torres Cabido
Journal:  BMC Musculoskelet Disord       Date:  2022-02-17       Impact factor: 2.362

3.  Correlation Between Habitual Physical Activity and Central Sensitization, Pain Intensity, Kinesiophobia, Catastrophizing, and the Severity of Myogenous Temporomandibular Disorder.

Authors:  Artur Eduardo Kalatakis-Dos-Santos; Cid André Fidelis-de-Paula-Gomes; Daniela Bassi-Dibai; Maria Cláudia Gonçalves; Paulo Henrique Martins-de-Sousa; Flávio de Oliveira Pires; Mariana Quixabeira Guimarães Almeida; Almir Vieira Dibai-Filho
Journal:  J Chiropr Med       Date:  2020-09-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.