Photorefractive intrastromal corneal crosslinking for treatment of myopic refractive error: Findings from 12-month prospective study using an epithelium-off protocol.

Matthias Elling1, Inga Kersten-Gomez2, H Burkhard Dick2.   

Abstract

PURPOSE: To assess the long-term effectiveness and safety of photorefractive intrastromal corneal crosslinking (CXL) in patients with low myopia.
SETTING: Ruhr University Eye Hospital, Bochum, Germany.
DESIGN: Prospective case series.
METHODS: Healthy eyes with myopia were treated with photorefractive intrastromal CXL using the Mosaic System. Riboflavin 0.1% solution (VibeX Rapid) was topically administered, followed by 365 nm ultraviolet-A (30 mW/cm2) irradiance. Efficacy was assessed by the uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), and keratometry. Safety was assessed by corrected distance visual acuity (CDVA), slitlamp biomicroscopy, endothelial cell count, and adverse event rates.
RESULTS: Fourteen patients (24 eyes) with a mean age of 35.7 years were included. At all follow-ups, a statistically significant improvement in UDVA was observed (all P < .001). The CDVA progressively improved from 1 month postoperatively and a statistically significant improvement was achieved at 12 months (P < .001). The average reduction in manifest sphere was 0.90 diopter (D) ± 0.40 (SD) by 12 months. There were no significant differences in mean manifest sphere and MRSE at 3, 6, or 12 months. Compared with baseline, significant reductions in corneal curvature were also observed at all follow-ups (all P < .05). There were no significant changes in endothelial cell density (P = 1.00) or number of cells (P = .95) at 12 months postoperatively, and no adverse events were reported.
CONCLUSION: Photorefractive intrastromal CXL was a safe and efficacious treatment of refractive error in patients with low myopia.
Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29778107     DOI: 10.1016/j.jcrs.2018.01.022

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  Nonlinear optical crosslinking (NLO CXL) for correcting refractive errors.

Authors:  Samantha Bradford; Eric Mikula; Tibor Juhasz; Donald J Brown; James V Jester
Journal:  Exp Eye Res       Date:  2020-08-23       Impact factor: 3.467

2.  Optical coherence elastography by ambient pressure modulation for high-resolution strain mapping applied to patterned cross-linking.

Authors:  Sabine Kling
Journal:  J R Soc Interface       Date:  2020-01-22       Impact factor: 4.118

Review 3.  A Review of Structural and Biomechanical Changes in the Cornea in Aging, Disease, and Photochemical Crosslinking.

Authors:  Brecken J Blackburn; Michael W Jenkins; Andrew M Rollins; William J Dupps
Journal:  Front Bioeng Biotechnol       Date:  2019-03-29

4.  Corneal Crosslinking in Refractive Corrections.

Authors:  Viral V Juthani; Roy S Chuck
Journal:  Transl Vis Sci Technol       Date:  2021-04-29       Impact factor: 3.283

Review 5.  Corneal Cross-Linking: The Evolution of Treatment for Corneal Diseases.

Authors:  Duoduo Wu; Dawn Ka-Ann Lim; Blanche Xiao Hong Lim; Nathan Wong; Farhad Hafezi; Ray Manotosh; Chris Hong Long Lim
Journal:  Front Pharmacol       Date:  2021-07-19       Impact factor: 5.810

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.