Literature DB >> 29778043

Investigation of interactions of Comtan with human serum albumin by mathematically modeled voltammetric data: A study from bio-interaction to biosensing.

Ali R Jalalvand1, Sirous Ghobadi2, Hector C Goicoechea3, Hui-Wen Gu4, Esmael Sanchooli5.   

Abstract

In this work, voltammetric data recorded at a glassy carbon electrode (GCE) were separately used to investigate the interactions of entacapone (Comtan, CAT) with human serum albumin (HSA). Then, an augmented data matrix was constructed by the combination of voltammetric and spectroscopic data and simultaneously analysed by multivariate curve resolution-alternating least squares (MCR-ALS) to obtain more information about CAT-HSA interactions. The absence of rotational ambiguities in results obtained by MCR-ALS was verified with the help of MCR-BANDS and we confirmed that the results were unambiguous and reliable. Binding of CAT to HSA was also modeled by molecular docking and the results were compatible with those of obtained by recording experimental data. Hard-modeling of combined voltammetric and spectroscopic data by EQUISPEC as an efficient chemometric algorithm helped us to compute binding constant of CAT-HSA complex specie which was in a good agreement with the binding constant value obtained by direct analysis of experimental data. For electrochemical sensing of serum albumin two amperometric measurements were performed to determine HSA in 2-27 nM and 27-70 nM with a limit of detection of 0.51 nM and a sensitivity of 1.84 μA nM-1.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Comtan; Human serum albumin; Interaction

Mesh:

Substances:

Year:  2018        PMID: 29778043     DOI: 10.1016/j.bioelechem.2018.05.008

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  4 in total

1.  Developing an elegant and integrated electrochemical-theoretical approach for detection of DNA damage induced by 4-nonylphenol.

Authors:  Kazhal Ghanbari; Mahmoud Roshani; Hector C Goicoechea; Ali R Jalalvand
Journal:  Heliyon       Date:  2019-11-01

2.  Introducing an interesting and novel strategy based on exploiting first-order advantage from spectrofluorimetric data for monitoring three toxic metals in living cells.

Authors:  Vali Akbari; Elaheh Jamasbi; Shahla Korani; Hamid-Reza Mohammadi-Motlagh; Ghobad Mohammadi; Ali R Jalalvand
Journal:  Toxicol Rep       Date:  2022-04-01

3.  Coupling of digital image processing and three-way calibration to assist a paper-based sensor for determination of nitrite in food samples.

Authors:  Zohreh Almasvandi; Ali Vahidinia; Ali Heshmati; Mohammad Mahdi Zangeneh; Hector C Goicoechea; Ali R Jalalvand
Journal:  RSC Adv       Date:  2020-04-08       Impact factor: 3.361

4.  Matrix augmentation as an efficient method for resolving interaction of bromocriptine with human serum albumin: trouble shooting and simultaneous resolution.

Authors:  Ali R Jalalvand; Sirous Ghobadi; Hector C Goicoechea; Elahe Faramarzi; Majid Mahmoudi
Journal:  Heliyon       Date:  2019-07-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.