Literature DB >> 29776548

A label-free electrochemical biosensor for direct detection of RACK 1 by using disposable, low-cost and reproducible ITO based electrode.

Hakan Törer1, Elif Burcu Aydın2, Mustafa Kemal Sezgintürk3.   

Abstract

In this study we designed an ultrasensitive electrochemical immunosensor for RACK 1 detection using 11-cyanoundecyltrimethoxysilane (11-CUTMS) as a immobilization matrix to immobilize biorecognition element. The used silane agent (11-CUTMS) provides a favorable platform for efficient loading of anti-RACK 1 antibody. The effective loading of the biorecognition element on the 11-CUTMS matrix was monitored by scanning electron microscopy (SEM), atomic force microscopy (AFM) images and fourier transform infrared spectroscopy (FTIR) spectra. The electrochemical characterization of the immunosensor was performed by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Moreover, biorecognition interaction between anti-RACK1 antibodies and RACK1 antigens was monitored by using single frequency technique (SFI). The operating conditions, calibration curves obtained during optimization of experiments and reproducibility of the proposed impedimetric RACK1 biosensor are also investigated and discussed. The electrochemical immunosensor illustrated a sensitive response to RACK 1 antigen with detection limit of 10.8 fg/mL and in the linear range of 0.036-2.278 pg/mL (R2 = 0.999). Owing to high specificity, good reproducibility, long stability and reusability, the fabricated immunosensor will provide a sensitive, selective approach to RACK 1 detection. Furthermore, the practical applicability in human serum samples were investigated with a satisfactory result.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  11-cyanoundecyltrimethoxysilane; Biosensor; ITO; RACK1; Receptor of activated C kinase

Mesh:

Substances:

Year:  2018        PMID: 29776548     DOI: 10.1016/j.aca.2018.04.031

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  A direct and simple immobilization route for immunosensors by CNBr activation for covalent attachment of anti-leptin: obesity diagnosis point of view.

Authors:  İnci Uludağ; Mustafa Kemal Sezgintürk
Journal:  3 Biotech       Date:  2022-01-03       Impact factor: 2.406

2.  Rapid thermal annealing for high-quality ITO thin films deposited by radio-frequency magnetron sputtering.

Authors:  Petronela Prepelita; Ionel Stavarache; Doina Craciun; Florin Garoi; Catalin Negrila; Beatrice Gabriela Sbarcea; Valentin Craciun
Journal:  Beilstein J Nanotechnol       Date:  2019-07-25       Impact factor: 3.649

Review 3.  Recent Advances in Electrochemical Sensors for the Detection of Biomolecules and Whole Cells.

Authors:  Intan Rosalina Suhito; Kyeong-Mo Koo; Tae-Hyung Kim
Journal:  Biomedicines       Date:  2020-12-26
  3 in total