Literature DB >> 29776538

Rapid detection of CALR type 1 and type 2 mutations using PNA-LNA clamping loop-mediated isothermal amplification on a CD-like microfluidic chip.

Guojun Cao1, Jilie Kong2, Zhifang Xing3, Yigui Tang1, Xinju Zhang4, Xiao Xu4, Zhihua Kang1, Xueen Fang5, Ming Guan6.   

Abstract

Bleeding and thrombosis represent common complications in myeloproliferative neoplasms (MPN) and significantly contribute to morbidity and mortality. Molecular markers, including CALR mutations, were considered not only as diagnostic markers, but also as risk factors for bleeding and thrombosis associated with MPN, especially for patients in remote primary hospitals. We sought to develop an easy-to-use assay for the rapid detection of CALR type 1 (CALR-1) and type 2 (CALR-2) mutations in Philadelphia chromosome-negative MPN patients. Peptide nucleic acid-locked nucleic acid (PNA-LNA) clamping loop-mediated isothermal amplification (LAMP) assays were established, which were integrated into a centrifugal compact disc (CD) microfluidic platform. A total of 158 clinical blood samples were tested simultaneously by this microfluidic platform and an in-house real time PCR assay. The detection performance of the LAMP arrays was validated and conflicting results were identified by Sanger sequencing. The results suggested that the LAMP methods we developed exhibited good sensitivity, specificity, and precision. By real time fluorescence assay the detection limit for CALR-1 and CALR-2 mutations could reach as low as 1% and 0.5% respectively, and 10% and 5% respectively by visual method. There were no nonspecific background amplifications among different detection systems. For the CALR-1 and CALR-2 LAMP detection systems, intra-batch CV values of 1% mutated plasmid were 10.56% and 10.51% respectively, and the inter-batch CV values were 19.55% and 18.39%, respectively. The products were all analyzed by melting curve analysis and electrophoresis followed by Sanger sequencing analysis, which were consistent with the database sequences. The microfluidic platform could complete rapid detection of CALR-1/2 mutations within 60 min. The results of clinical samples detected by our CD-like microfluidic chipLAMP assay and rtPCR assay suggested that 133 samples were CALR wild type, 15 were CALR-1 mutation type, and 9 were CALR-2 mutation type. The correlation coefficient value (Kendall's tau_b) of the two assays was 0.99. Interestingly, by the newly established detection platform, we were surprised to find that one patient of Chinese origin harbored both CALR-1 and CALR-2 mutations. This result was verified by Sanger sequencing analysis. The LAMP detection systems developed herein displayed good sensitivity, specificity, and stability. Additionally, the detection results could be directly judged by color changes of the reaction systems without any auxiliary equipment. Thus, the platform we developed has the potential of being widely used in remote and economically undeveloped areas in the future.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CALR mutation; CD-Like microfluidic chip; Locked nucleic acid (LNA); Loop-mediated isothermal amplification (LAMP); Peptide nucleic acid (PNA); Point-of-care testing (POCT)

Mesh:

Substances:

Year:  2018        PMID: 29776538     DOI: 10.1016/j.aca.2018.04.022

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Production and Characterization of Peptide Antibodies to the C-Terminal of Frameshifted Calreticulin Associated with Myeloproliferative Diseases.

Authors:  Farah Perveen Mughal; Ann Christina Bergmann; Ha Uyen Buu Huynh; Sarah Hyllekvist Jørgensen; Inaam Mansha; Meliha Kesmez; Patrick Mark Schürch; Alexandre Pierre André Theocharides; Paul Robert Hansen; Tina Friis; Morten Orebo Holmström; Evaldas Ciplys; Rimantas Slibinskas; Peter Højrup; Gunnar Houen; Nicole Hartwig Trier
Journal:  Int J Mol Sci       Date:  2022-06-18       Impact factor: 6.208

Review 2.  AS-LAMP: A New and Alternative Method for Genotyping.

Authors:  Pooria Gill; Arash Hadian Amree
Journal:  Avicenna J Med Biotechnol       Date:  2020 Jan-Mar
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.