Literature DB >> 29768732

The effect of light intensity on image quality in endoscopic ear surgery.

R McCallum1, J McColl2, A Iyer1.   

Abstract

OBJECTIVES: Endoscopic ear surgery is a rapidly developing field with many advantages. But endoscopes can reach temperatures of over 110°C at the tip, raising safety concerns. Reducing the intensity of the light source reduces temperatures produced. However, quality of images at lower light intensities has not yet been studied. We set out to study the effect of light intensity on image quality in EES.
DESIGN: Prospective study of patients undergoing EES from April to October 2016. Consecutive images of the same operative field at 10%, 30%, 50% and 100% light intensities were taken. Eight international experts were asked to each evaluate 100 anonymised, randomised images.
SETTING: District General Hospital. PARTICIPANTS: Twenty patients. MAIN OUTCOME MEASURES: Images were evaluated on a 5-point Likert scale (1 = significantly worse than average; 5 = significantly better than average) for detail of anatomy; colour contrast; overall quality; and suitability for operating.
RESULTS: Mean scores for photographs at 10%, 30%, 50% and 100% light intensity were 3.22 (SD 0.93), 3.15 (SD 0.84), 3.08 (SD 0.88) and 3.10 (SD 0.86), respectively. In ANOVA models for the scores on each of the scales (anatomy, colour contrast, overall quality and suitability for operating), the effects of rater and patient were highly significant (P < .0005) but light intensity was non-significant (P = .34, .32, .21, .15, respectively).
CONCLUSION: Images taken during surgery by our endoscope and operative camera have no loss of quality when taken at lower light intensities. We recommend the surgeon considers use of lower light intensities in endoscopic ear surgery.
© 2018 John Wiley & Sons Ltd.

Entities:  

Keywords:  endoscopes; hot temperature; image enhancements; otologic surgical procedures

Mesh:

Year:  2018        PMID: 29768732     DOI: 10.1111/coa.13139

Source DB:  PubMed          Journal:  Clin Otolaryngol        ISSN: 1749-4478            Impact factor:   2.597


  2 in total

1.  Thermal Safety of Endoscopic Usage in Robot-Assisted Middle Ear Surgery: An Experimental Study.

Authors:  Jinxi Pan; Haoyue Tan; Jun Shi; Zhaoyan Wang; Olivier Sterkers; Huan Jia; Hao Wu
Journal:  Front Surg       Date:  2021-05-14

Review 2.  Getting started in endoscopic ear surgery.

Authors:  Peter Ryan; Carolina Wuesthoff; Nirmal Patel
Journal:  J Otol       Date:  2018-11-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.