Jacob Laughner1, Shibaji Shome1, Nicholas Child2, Allan Shuros1, Petr Neuzil3, Jaswinder Gill2, Matthew Wright4. 1. Boston Scientific St. Paul, Minnesota, USA. 2. Kings College London BHF Centre, Cardiovascular Division, NIHR Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom. 3. Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic. 4. Kings College London BHF Centre, Cardiovascular Division, NIHR Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom. Electronic address: matthew.wright@kcl.ac.uk.
Abstract
OBJECTIVES: This study sought to evaluate basket catheter deployment, catheter-tissue contact, and time-space stability of unipolar atrial electrograms (aEGMs) recorded in persistent atrial fibrillation (AF) patients. BACKGROUND: Panoramic mapping of human AF using multiple-electrode basket catheters may identify AF sources. Although clinical results using this technique are provocative, questions remain about its effectiveness. METHODS: Data were collected from patients (N = 25) undergoing catheter ablation for AF during the multicenter STARLIGHT (Signal Transfer of Atrial Fibrillation Data to Guide Human Treatment) trial (NCT01765075). Left and right aEGM signals were recorded using basket catheters during baseline AF, following ablation and during sinus rhythm. Data were analyzed for basket deployment, peak-to-peak voltage, and electrogram stability and organization. Electrogram stability and organization were evaluated via time-frequency analysis (TFA). RESULTS: Basket catheters displayed equatorial bunching when deployed in atria. Interspline spacing ranged from 1.7 to 64.0 mm in the right atrial and from 1.5 to 85.08 mm in the left atrial basket. Approximately one-third of mapping electrodes failed to demonstrate a median peak-to-peak voltage >2× the low-voltage threshold. Time-space stability and organization was observed in 13 of 22 (59.09%) right atrial and 10 of 22 (45.45%) left atrial baskets. CONCLUSIONS: Despite poor deployment and a large number of low-voltage electrodes, stability and organization was observed in about one-half of the mapped patients. Although this study suggests that basket catheters have limitations for patient-specific AF mapping, concordant activation occurs in some persistent AF patients, which may be amenable to high-density mapping techniques.
OBJECTIVES: This study sought to evaluate basket catheter deployment, catheter-tissue contact, and time-space stability of unipolar atrial electrograms (aEGMs) recorded in persistent atrial fibrillation (AF) patients. BACKGROUND: Panoramic mapping of humanAF using multiple-electrode basket catheters may identify AF sources. Although clinical results using this technique are provocative, questions remain about its effectiveness. METHODS: Data were collected from patients (N = 25) undergoing catheter ablation for AF during the multicenter STARLIGHT (Signal Transfer of Atrial Fibrillation Data to Guide Human Treatment) trial (NCT01765075). Left and right aEGM signals were recorded using basket catheters during baseline AF, following ablation and during sinus rhythm. Data were analyzed for basket deployment, peak-to-peak voltage, and electrogram stability and organization. Electrogram stability and organization were evaluated via time-frequency analysis (TFA). RESULTS: Basket catheters displayed equatorial bunching when deployed in atria. Interspline spacing ranged from 1.7 to 64.0 mm in the right atrial and from 1.5 to 85.08 mm in the left atrial basket. Approximately one-third of mapping electrodes failed to demonstrate a median peak-to-peak voltage >2× the low-voltage threshold. Time-space stability and organization was observed in 13 of 22 (59.09%) right atrial and 10 of 22 (45.45%) left atrial baskets. CONCLUSIONS: Despite poor deployment and a large number of low-voltage electrodes, stability and organization was observed in about one-half of the mapped patients. Although this study suggests that basket catheters have limitations for patient-specific AF mapping, concordant activation occurs in some persistent AFpatients, which may be amenable to high-density mapping techniques.
Authors: Andrew Grace; Stephan Willems; Christian Meyer; Atul Verma; Patrick Heck; Min Zhu; Xinwei Shi; Derrick Chou; Lam Dang; Christoph Scharf; Günter Scharf; Graydon Beatty Journal: JCI Insight Date: 2019-03-21
Authors: Barbara Bellmann; Tina Lin; Peter Ruppersberg; Marit Zettwitz; Selma Guttmann; Verena Tscholl; Patrick Nagel; Mattias Roser; Ulf Landmesser; Andreas Rillig Journal: Clin Res Cardiol Date: 2018-05-09 Impact factor: 5.460
Authors: Tobias Oesterlein; Daniel Frisch; Axel Loewe; Gunnar Seemann; Claus Schmitt; Olaf Dössel; Armin Luik Journal: Biomed Res Int Date: 2016-12-13 Impact factor: 3.411
Authors: Caroline H Roney; Chris D Cantwell; Jason D Bayer; Norman A Qureshi; Phang Boon Lim; Jennifer H Tweedy; Prapa Kanagaratnam; Nicholas S Peters; Edward J Vigmond; Fu Siong Ng Journal: Circ Arrhythm Electrophysiol Date: 2017-05