Literature DB >> 29763343

Clinical and Patient-Related Outcomes of a Tapered Implant System With Switched Platform Conical Abutments: A Private Practice Field Trial.

Jacob Horwitz1,2, Eli E Machtei1,2, Shai Frankental1, Eran Gabay1, Yaniv Mayer1, Livia Joseph3, Omer Cohen4.   

Abstract

The aim of this prospective cohort observational field trial was to examine 1-year survival and success rates of a recently introduced tapered implant system with switched platform conical abutments and to evaluate patient related outcomes of therapy. Partially edentulous patients aged between 18 and 75 years, with available bone height for dental implants ≥10 mm desiring to restore the missing tooth/teeth with implant supported restoration, were recruited by 7 periodontists in their respective private practices. Dental implants were installed according to standard implant therapy protocol. Three to 6 months postoperatively, after evaluating interim implant success, implants were restored by the referring dentists. Patient, Ramfjord teeth, and implant data, including baseline and 1-year postoperative, were collected. A total of 60 patients were recruited and received 117 implants. Complete 1-year clinical and radiographic data were available for 83 and 65 implants, respectively. Two implants failed during the first year, resulting in a 1-year survival rate of 98.3%. Mean implant probing pocket depth was 2.29 ± 0.84 mm. Mean radiographic bone distance from implant's shoulder at the mesial and distal sites at 1 year was 0.66 ± 0.5 and 0.79 ± 0.64mm, respectively, resulting in a success rate of 95.4%. Patient subjective evaluation of therapy exhibited a median pain experience of 1 and median esthetics, function, and general satisfaction evaluation of 10 on a scale of 1 to 10. The tapered conical connection dental implant system, used in private dental practices, shows good 1-year survival and success rates that are similar to other implant systems on the market.

Entities:  

Keywords:  dental implant; field study; private practices; radiology

Mesh:

Substances:

Year:  2018        PMID: 29763343     DOI: 10.1563/aaid-joi-D-18-00005

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  1 in total

1.  Covariates Relating to Implant Failure and Marginal Bone Loss of a Novel Triangular Neck-Implant Placed by Post-Graduate Students: A 1-Year Prospective Cohort Study.

Authors:  Maria Giralt-Hernando; Gian Maria Ragucci; Oriol Cantó-Naves; Adaia Valls-Ontañón; Federico Hernández-Alfaro
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  1 in total