US Time-Harmonic Elastography: Detection of Liver Fibrosis in Adolescents with Extreme Obesity with Nonalcoholic Fatty Liver Disease.

Christian A Hudert1, Heiko Tzschätzsch1, Jing Guo1, Birgit Rudolph1, Hendrik Bläker1, Christoph Loddenkemper1, Werner Luck1, Hans-Peter Müller1, Daniel C Baumgart1, Bernd Hamm1, Jürgen Braun1, Hermann-Georg Holzhütter1, Susanna Wiegand1, Ingolf Sack1.   

Abstract

Purpose To measure in vivo liver stiffness by using US time-harmonic elastography in a cohort of pediatric patients who were overweight to extremely obese with nonalcoholic fatty liver disease (NAFLD) and to evaluate the diagnostic value of time-harmonic elastography for differentiating stages of fibrosis associated with progressive disease. Materials and Methods In this prospective study, 67 consecutive adolescents (age range, 10-17 years; mean body mass index, 34.7 kg/m2; range, 21.4-50.4 kg/m2) with biopsy-proven NAFLD were enrolled. Liver stiffness was measured by using time-harmonic elastography based on externally induced continuous vibrations of 30 Hz to 60 Hz frequency and real-time B-mode-guided wave profile analysis covering tissue depths of up to 14 cm. The diagnostic accuracy of time-harmonic elastography in staging liver fibrosis was assessed with area under the receiver operating characteristic curve (AUC) analysis. Liver stiffness cutoffs for the differentiation of fibrosis stages were identified based on the highest Youden index. Results Time-harmonic elastography was feasible in all patients (0% failure rate), including 70% (n = 47) of individuals with extreme obesity (body mass index above the 99.5th percentile). AUC analysis for the detection of any fibrosis (≥ stage F1), moderate fibrosis (≥ stage F2), and advanced fibrosis (≥ stage F3) was 0.88 (95% confidence interval [CI]: 0.80, 0.96), 0.99 (95% CI: 0.98, 1.00), and 0.88 (95% CI: 0.80, 0.96), respectively. The best liver stiffness cutoffs were 1.52 m/sec for at least stage F1, 1.62 m/sec for at least stage F2, and 1.64 m/sec for at least stage F3. Conclusion US time-harmonic elastography allows accurate detection of moderate fibrosis even in pediatric patients with extreme obesity. Larger clinical trials are warranted to confirm the accuracy of US time-harmonic elastography. © RSNA, 2018 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2018        PMID: 29762096     DOI: 10.1148/radiol.2018172928

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  In vivo time-harmonic ultrasound elastography of the human brain detects acute cerebral stiffness changes induced by intracranial pressure variations.

Authors:  Heiko Tzschätzsch; Bernhard Kreft; Felix Schrank; Judith Bergs; Jürgen Braun; Ingolf Sack
Journal:  Sci Rep       Date:  2018-12-17       Impact factor: 4.379

2.  The assessment of liver fibrosis in children with obesity on two methods: transient and two dimensional shear wave elastography.

Authors:  Cristina Oana Mărginean; Lorena Elena Meliţ; Dana Valentina Ghiga; Maria Oana Săsăran
Journal:  Sci Rep       Date:  2019-12-24       Impact factor: 4.379

3.  Changes in Liver Mechanical Properties and Water Diffusivity During Normal Pregnancy Are Driven by Cellular Hypertrophy.

Authors:  Karolina Garczyńska; Heiko Tzschätzsch; Anja A Kühl; Anna Sophie Morr; Ledia Lilaj; Akvile Häckel; Eyk Schellenberger; Nikolaus Berndt; Hermann-Georg Holzhütter; Jürgen Braun; Ingolf Sack; Jing Guo
Journal:  Front Physiol       Date:  2020-11-23       Impact factor: 4.566

4.  Performance of Imaging Techniques in Non-invasive Diagnosis of Non-alcoholic Fatty Liver Disease in Children: A Systematic Review and Meta-Analysis.

Authors:  Qun Yu; Yiwei Liu; Peipei Hu; Feng Gao; Guoqing Huang
Journal:  Front Pediatr       Date:  2022-07-11       Impact factor: 3.569

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.