Literature DB >> 29761902

The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis.

Riccardo Caricasulo1, Luciano Malchiodi2, Paolo Ghensi3, Giuliano Fantozzi4, Alessandro Cucchi5.   

Abstract

PURPOSE: Different implant-abutment connections are available and it has been claimed they could have an effect on marginal bone loss. The aim of this review is to establish if implant connection configuration influences peri-implant bone loss (PBL) after functional loading.
METHODS: A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Does the type of implant-abutment connection (external, internal, or conical) have an influence on peri-implant bone loss? A PubMed/MEDLINE electronic search was conducted to identify English language publications published in international journals during the last decade (from 2006 to 2016). The search was conducted by using the Medical Subject Headings (MeSH) keywords "dental implants OR dental abutment AND external connection OR internal connection OR conical connection OR Morse Taper." Selected studies were randomized clinical trials and prospective studies; in vitro studies, case reports and retrospective studies were excluded. Titles and abstracts and, in the second phase, full texts, were evaluated autonomously and in duplicate by two reviewers.
RESULTS: A total of 1649 articles were found, but only 14 studies met the pre-established inclusion criteria and were considered suitable for meta-analytic analysis. The network meta-analysis (NMA) suggested a significant difference between the external and the conical connections; this was less evident for the internal and conical ones. Platform-switching (PS) seemed to positively affect bone levels, non-regarding the implant-connection it was applied to.
CONCLUSIONS: Within the limitations of this systematic review, it can be concluded that crestal bone levels are better maintained in the short-medium term when internal kinds of interface are adopted. In particular, conical connections seem to be more advantageous, showing lower peri-implant bone loss, but further studies are necessary to investigate the efficacy of implant-abutment connection on stability of crestal bone levels.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone levels; dental implant; implant-abutment connection; peri-implant bone loss; systematic review

Mesh:

Substances:

Year:  2018        PMID: 29761902     DOI: 10.1111/cid.12620

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  20 in total

1.  Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study.

Authors:  Qian Ding; Qiang Luo; Yajing Tian; Lei Zhang; Qiufei Xie; Yongsheng Zhou
Journal:  Clin Oral Investig       Date:  2022-02-07       Impact factor: 3.573

2.  Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.

Authors:  James Rudolph Collins; Brendha P Ogando; Houlin Hong; Wei Hou; Georgios E Romanos
Journal:  Dent J (Basel)       Date:  2022-06-16

3.  Immediate Placement and Restoration of a New Tapered Implant System in the Aesthetic Region: A Report of Three Cases.

Authors:  Caroliene M Meijndert; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Case Rep Dent       Date:  2020-07-25

4.  Variations in vertical mucosal thickness at edentulous ridge according to site and gender measured by cone-beam computed tomography.

Authors:  Motohiro Munakata; Koudai Nagata; Minoru Sanda; Ryota Kawamata; Daisuke Sato; Kikue Yamaguchi
Journal:  Int J Implant Dent       Date:  2021-05-12

5.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

6.  Radiographic bone level around particular laser-treated dental implants: 1 to 6 years multicenter retrospective study.

Authors:  C Mongardini; B Zeza; P Pelagalli; R Blasone; M Scilla; M Berardini
Journal:  Int J Implant Dent       Date:  2020-07-28

7.  Peri-Implant Bone Resorption during Healing Abutment Placement: The Effect of a 0.20% Chlorhexidine Gel vs. Placebo-A Randomized Double Blind Controlled Human Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Ilaria De Tullio; Tonino Traini; Sergio Caputi
Journal:  Biomed Res Int       Date:  2018-10-16       Impact factor: 3.411

8.  Immunohistochemical Results of Soft tissues Around a New Implant Healing-Abutment Surface: A Human Study.

Authors:  Barbara Ghinassi; Gianmaria D'Addazio; Angela Di Baldassarre; Beatrice Femminella; Giorgio Di Vincenzo; Maurizio Piattelli; Giulia Gaggi; Bruna Sinjari
Journal:  J Clin Med       Date:  2020-04-02       Impact factor: 4.241

9.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

10.  A 4 Year Human, Randomized, Radiographic Study of Scalloped versus Non-Scalloped Cemented Implants.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Manlio Santilli; Barbara D'Avanzo; Imena Rexhepi; Antonio Scarano; Tonino Traini; Maurizio Piattelli; Sergio Caputi
Journal:  Materials (Basel)       Date:  2020-05-10       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.