Abstract
In these days, wearable devices have been developed for effectively measuring biological data. However, these devices have tissue allege and noise problem. To solve these problems, biometric measurement based on a non-contact method, such as face image sequencing is developed. This makes it possible to measure biometric data without any operation and side effects. However, it is impossible for a remote center to identify the person whose data are measured by the novel methods. In this paper, we propose the novel non-contact heart rate and blood pressure imaging system, Deep Health Eye. This system has authentication process at the same time as measuring bio signals, through non-contact method. In the future, this system can be convenient home bio signal monitoring system by combined with smart mirror.Entities:
Keywords: Partial pressure suit; circulatory physiology; counter pressure; numerical model
Mesh:
Year: 2018 PMID: 29758958 PMCID: PMC6004981 DOI: 10.3233/THC-174569
Source DB: PubMed Journal: Technol Health Care ISSN: 0928-7329 Impact factor: 1.285
The minimum, maximum and mean error values of each algorithm
| Error | TPRL | TPS-RPM | ICP | SC |
|---|---|---|---|---|
| Mean Error | 4.771 | 4.854 | 4.872 | 6.844 |
| Min Error | 3.002 | 2.190 | 2.169 | 3.825 |
| Max Error | 7.510 | 9.185 | 8.873 | 1.355 |
The error values of the rotation test
| Rotation | TPRL | TPS-RPM | ICP | SC |
|---|---|---|---|---|
| Right 5 | 5.557 | 6.261 | 7.772 | 5.919 |
| Right 10 | 6.876 | 8.340 | 8.517 | 1.034 |
| Right 15 | 6.563 | 7.339 | 7.547 | 7.937 |
| Right 20 | 7.028 | 8.906 | 1.240 | 7.880 |
| Left 5 | 5.365 | 7.647 | 1.044 | 8.162 |
| Left 10 | 5.234 | 8.208 | 9.327 | 8.872 |
| Left 15 | 6.157 | 7.620 | 9.949 | 1.001 |
| Left 20 | 7.256 | 1.073 | 1.317 | 1.026 |
The error values of the noise test
| Noise | TPRL | TPS-RPM | ICP | SC |
|---|---|---|---|---|
| 0% | 4.774 | 7.831 | 1.002 | 9.183 |
| 10% | 5.037 | 7.778 | 1.072 | 8.852 |
| 20% | 5.060 | 7.864 | 1.042 | 9.045 |
| 30% | 5.137 | 7.901 | 9.476 | 8.730 |
The error values of the occlusion test
| Occlusion | TPRL | TPS-RPM | ICP | SC |
|---|---|---|---|---|
| 0% | 5.200 | 6.666 | 7.100 | 7.323 |
| 10% | 6.713 | 7.732 | 6.889 | 1.056 |
| 20% | 6.867 | 7.906 | 7.093 | 1.459 |
| 30% | 7.998 | 1.423 | 8.490 | 1.601 |