Hsun-Liang Chan1, Khaled Sinjab1, Junying Li1,2, Zhaozhao Chen1,2, Hom-Lay Wang1,2, Oliver D Kripfgans3,4. 1. Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan. 2. Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China. 3. Department of Biomedical Engineering, College of Engineering, Ann Arbor, Michigan. 4. Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan.
Abstract
AIM: Existing methods for evaluating marginal bone loss and tissue biotype around dental implants present with many limitations. The aim of this study was to examine the accuracy of high-resolution, 3-dimensional ultrasound to measure peri-implant tissue dimensions. MATERIAL AND METHODS: A 25-MHz ultrasound probe prototype was used to scan peri-implant tissues of 17 implants from seven fresh human cadavers. Four ultrasonic measurements were made as follows: the marginal bone level/thickness, and mucosal level/thickness. The readings were statistically compared to cone beam computed tomography (CBCT) and/or open bone measurements. RESULTS: The correlations (r) between the ultrasound and direct/CBCT readings of the four parameters ranged from 0.85 to 0.98 (p < 0.0001). The mean absolute difference in the four parameters between ultrasound-direct and ultrasound-CBCT ranged from 0.033 to 0.24 mm. CONCLUSION: Encouraging evidence is shown that ultrasound can accurately measure peri-implant tissue dimensions. Following clinical trial validations, ultrasound offers potential as a valuable tool to evaluate long-term peri-implant tissue stability without concerns of ionizing radiation and image artefacts around implants.
AIM: Existing methods for evaluating marginal bone loss and tissue biotype around dental implants present with many limitations. The aim of this study was to examine the accuracy of high-resolution, 3-dimensional ultrasound to measure peri-implant tissue dimensions. MATERIAL AND METHODS: A 25-MHz ultrasound probe prototype was used to scan peri-implant tissues of 17 implants from seven fresh human cadavers. Four ultrasonic measurements were made as follows: the marginal bone level/thickness, and mucosal level/thickness. The readings were statistically compared to cone beam computed tomography (CBCT) and/or open bone measurements. RESULTS: The correlations (r) between the ultrasound and direct/CBCT readings of the four parameters ranged from 0.85 to 0.98 (p < 0.0001). The mean absolute difference in the four parameters between ultrasound-direct and ultrasound-CBCT ranged from 0.033 to 0.24 mm. CONCLUSION: Encouraging evidence is shown that ultrasound can accurately measure peri-implant tissue dimensions. Following clinical trial validations, ultrasound offers potential as a valuable tool to evaluate long-term peri-implant tissue stability without concerns of ionizing radiation and image artefacts around implants.
Authors: Mohamed Elbarbary; Adam Sgro; Saber Khazaei; Michael Goldberg; Howard C Tenenbaum; Amir Azarpazhooh Journal: Clin Oral Investig Date: 2022-01-14 Impact factor: 3.573
Authors: Tiago Marques; Sara Ramos; Nuno Bernardo Malta Dos Santos; Tiago Borges; Javier Montero; André Correia; Gustavo Vicentis de Oliveira Fernandes Journal: Dent J (Basel) Date: 2022-06-13