Literature DB >> 29754393

Predicting stress urinary incontinence during pregnancy: combination of pelvic floor ultrasound parameters and clinical factors.

Ling Chen1, Dan Luo1, Xiajuan Yu1,2, Mei Jin1, Wenzhi Cai1.   

Abstract

INTRODUCTION: The aim of this study was to develop and validate a predictive tool that combines pelvic floor ultrasound parameters and clinical factors for stress urinary incontinence during pregnancy.
MATERIAL AND METHODS: A total of 535 women in the first or second trimester of pregnancy were included for an interview and transperineal ultrasound assessment from two hospitals. Imaging data sets were analyzed offline to assess for bladder neck vertical position, urethra angles (α, β and γ angles), hiatal area and bladder neck funneling. All significant continuous variables at univariable analysis were analyzed by receiver operating characteristics. Three multivariable logistic models were built on clinical factors, and combined with ultrasound parameters. The final predictive model with best performance and fewest variables was selected to establish a nomogram. Internal and external validation of the nomogram was performed by both discrimination represented by C-index and calibration measured by Hosmer-Lemeshow test. A decision curve analysis was conducted to determine the clinical utility of the nomogram.
RESULTS: After excluding 14 women with invalid data, 521 women were analyzed. β angle, γ angle and hiatal area had limited predictive value for stress urinary incontinence during pregnancy, with area under curves of 0.558-0.648. The final predictive model included body mass index gain since pregnancy, constipation, previous delivery mode, β angle at rest, and bladder neck funneling. The nomogram based on the final model showed good discrimination with a C-index of 0.789 and satisfactory calibration (p = 0.828), both of which were supported by external validation. Decision curve analysis showed that the nomogram was clinically useful.
CONCLUSIONS: The nomogram incorporating both the pelvic floor ultrasound parameters and clinical factors has been validated to show good discrimination and calibration, and could be an important tool for stress urinary incontinence risk prediction at an early stage of pregnancy.
© 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

Entities:  

Keywords:  Pregnancy; risk prediction; stress urinary incontinence; transperineal ultrasound

Year:  2018        PMID: 29754393     DOI: 10.1111/aogs.13368

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  2 in total

1.  Hormonal Influence in Stress Urinary Incontinence During Pregnancy and Postpartum.

Authors:  Cristina Molinet Coll; Eva Martínez Franco; Laura Altimira Queral; Daniel Cuadras; Lluís Amat Tardiu; David Parés
Journal:  Reprod Sci       Date:  2022-04-26       Impact factor: 2.924

2.  Imaging with ultrasound in physical therapy: What is the PT's scope of practice? A competency-based educational model and training recommendations.

Authors:  Jackie L Whittaker; Richard Ellis; Paul William Hodges; Cliona OSullivan; Julie Hides; Samuel Fernandez-Carnero; Jose Luis Arias-Buria; Deydre S Teyhen; Maria J Stokes
Journal:  Br J Sports Med       Date:  2019-04-25       Impact factor: 13.800

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.