Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

Xiujuan Liu1, Haiquan Tao2, Xigang Xiao1, Binbin Guo3, Shangcai Xu4, Na Sun1, Maotong Li1, Li Xie3, Changjun Wu5.   

Abstract

OBJECTIVE: This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. PATIENTS AND METHODS: First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard.
RESULTS: Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms.
CONCLUSION: The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CT angiography; Digital subtraction angiography; Intracranial aneurysm; Virtual reality; Volume rendering

Mesh:

Year:  2018        PMID: 29753884     DOI: 10.1016/j.clineuro.2018.04.034

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  1 in total

1.  Does stereoscopic imaging improve the memorization of medical imaging by neurosurgeons? Experience of a single institution.

Authors:  Nicolas Schlinkmann; Rutvik Khakhar; Thomas Picht; Sophie K Piper; Lucius S Fekonja; Peter Vajkoczy; Gueliz Acker
Journal:  Neurosurg Rev       Date:  2021-09-22       Impact factor: 3.042