Literature DB >> 29753165

Diagnosis of EGFR exon21 L858R point mutation as lung cancer biomarker by electrochemical DNA biosensor based on reduced graphene oxide /functionalized ordered mesoporous carbon/Ni-oxytetracycline metallopolymer nanoparticles modified pencil graphite electrode.

Yalda Shoja1, Ahmad Kermanpur2, Fathallah Karimzadeh2.   

Abstract

In this present work we made a novel, fast, selective and sensitive electrochemical genobiosensor to detection of EGFR exon 21 point mutation based on two step electropolymerization of Ni(II)-oxytetracycline conducting metallopolymer nanoparticles (Ni-OTC NPs) on the surface of pencil graphite electrode (PGE) which was modified by reduced graphene oxide/carboxyl functionalized ordered mesoporous carbon (rGO/f-OMC) nanocomposite. ssDNA capture probe with amine groups at the5' end which applied as recognition element was immobilized on the rGO/f-OMC/PGE surface via the strong amide bond. Ni-OTC metallopolymer NPs were electropolymerized to rGO/ssDNA-OMC/PGE surface and then hybridization fallows through the peak current change in differential pulse voltammetry (DPV) using Ni-OTC NPs as a redox label. The biosensor was characterized by field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), FT-IR spectroscopy, energy dispersive X-ray spectroscopy (EDX), cyclic voltammetry and Nitrogen adsorption-desorption analysis. The Ni-OTC current response verified only the complementary sequence indicating a significant reduction current signal in comparison to single point mismatched and non-complementary and sequences. Under optimal conditions, the prepared biosensor showed long-term stability (21 days) with a wide linear range from 0.1 µM to 3 µM with high sensitivity (0.0188 mA/µM) and low detection limit (120 nM).
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cancer biomarker; EGFR mutations; Metallopolymer nanoparticles

Mesh:

Substances:

Year:  2018        PMID: 29753165     DOI: 10.1016/j.bios.2018.04.013

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Recent advances in graphene-based nanomaterials: properties, toxicity and applications in chemistry, biology and medicine.

Authors:  Jun Yao; Heng Wang; Min Chen; Mei Yang
Journal:  Mikrochim Acta       Date:  2019-06-01       Impact factor: 5.833

2.  A DNA based visual and colorimetric aggregation assay for the early growth factor receptor (EGFR) mutation by using unmodified gold nanoparticles.

Authors:  Santheraleka Ramanathan; Subash C B Gopinath; M K Md Arshad; Prabakaran Poopalan; Periasamy Anbu
Journal:  Mikrochim Acta       Date:  2019-07-18       Impact factor: 5.833

Review 3.  2D Materials in Development of Electrochemical Point-of-Care Cancer Screening Devices.

Authors:  Mohsen Mohammadniaei; Huynh Vu Nguyen; My Van Tieu; Min-Ho Lee
Journal:  Micromachines (Basel)       Date:  2019-09-30       Impact factor: 2.891

4.  Aluminosilicate Nanocomposite on Genosensor: A Prospective Voltammetry Platform for Epidermal Growth Factor Receptor Mutant Analysis in Non-small Cell Lung Cancer.

Authors:  Santheraleka Ramanathan; Subash C B Gopinath; M K Md Arshad; Prabakaran Poopalan; Periasamy Anbu; Thangavel Lakshmipriya; Farizul Hafiz Kasim
Journal:  Sci Rep       Date:  2019-11-19       Impact factor: 4.379

5.  Biosensors for Point Mutation Detection.

Authors:  Hanlin Jiang; Hui Xi; Mario Juhas; Yang Zhang
Journal:  Front Bioeng Biotechnol       Date:  2021-12-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.