Impact of 30 Day Readmission After Left Ventricular Assist Device Implantation.

Saurabh Gupta1, Rebecca J Cogswell2, Samit S Roy2, John R Spratt3, Kenneth K Liao3, Cindy M Martin2, Ranjit John3.   

Abstract

Early readmission (within 30 days) after left ventricular assist device (LVAD) implantation might be a marker for increased mortality. We retrospectively reviewed the records of 277 adults who underwent continuous-flow LVAD implantation from 2005 through 2015 at our institution. The baseline characteristics of patients who were (versus were not) readmitted within 30 days after LVAD implantation were compared. To assess the impact of 30 day readmission on long-term survival, we used multivariate Cox regression. We also compared the cardiac transplant rate between the two groups. Of the 277 patients, 217 (78.3%) underwent LVAD implantation as a bridge-to-transplant; 76 (27.4%) of the 277 were readmitted within 30 days. The most common reason for readmission was volume overload (23.6%), followed by gastrointestinal bleeding (15.8%). Male gender, previous smoking, a higher baseline creatinine level, higher Model for End Stage Liver Disease Excluding INR (MELD-XI) score, and postoperative gastrointestinal bleeding or stroke were each associated with 30 day readmission. In our final multivariate model, increased mortality was also associated with 30 day readmission (hazard ratio, 1.60; 95% confidence interval, 1.1-2.5). Among the 217 bridge-to-transplant patients, the cardiac transplant rate was similar between the two groups: 18.7 transplants per patient-year among those who were readmitted within 30 days versus 19.7 transplants per patient-year among those who were not (p = 0.26). Among our study patients, 30 day readmission after LVAD implantation was frequent and was associated with increased mortality. It is currently unclear whether the general health of those patients was a factor and whether efforts to reduce 30 day readmission would favorably affect longer-term patient outcomes.

Entities:  

Mesh:

Year:  2019        PMID: 29750684     DOI: 10.1097/MAT.0000000000000812

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Questionable utility of digoxin in left-ventricular assist device recipients: A multicenter, retrospective analysis.

Authors:  Mustafa M Ahmed; Henri Roukoz; Jaimin R Trivedi; Adarsh Bhan; Ashwin Ravichandran; Rahul Dhawan; Jennifer Cowger; Geetha Bhat; Emma J Birks; Mark S Slaughter; Rakesh Gopinathannair
Journal:  PLoS One       Date:  2019-11-25       Impact factor: 3.240

2.  Risk factors of readmission to acute care hospital among individuals with heart failure and left ventricular assist device (LVAD) at inpatient rehabilitation setting (STROBE compliant article).

Authors:  Yong Kyun Kim; Nomeda Balcetis; Richard Novitch; Mooyeon Oh-Park
Journal:  Medicine (Baltimore)       Date:  2020-12-24       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.