OBJECTIVE: This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain [SREP]) compared with temporal summation of pain (TSP), a standard index of central sensitization. METHODS: Thirty-five fibromyalgia (FM) patients and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1-second duration at the thenar eminence using a 300-g monofilament with 1 second interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5-second duration applied to the fingernail with a 30-second interstimulus interval). To evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. RESULTS: Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p < .001) but not in RA (p = .35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p < .008). Compared with TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% versus 64.6%), greater sensitivity (0.89 versus 0.57), and greater specificity (0.87 versus 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (intraclass correlations = 0.80), and moderate in RA (intraclass correlations = 0.68). CONCLUSIONS: SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared with a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.
OBJECTIVE: This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain [SREP]) compared with temporal summation of pain (TSP), a standard index of central sensitization. METHODS: Thirty-five fibromyalgia (FM) patients and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1-second duration at the thenar eminence using a 300-g monofilament with 1 second interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5-second duration applied to the fingernail with a 30-second interstimulus interval). To evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. RESULTS: Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p < .001) but not in RA (p = .35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p < .008). Compared with TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% versus 64.6%), greater sensitivity (0.89 versus 0.57), and greater specificity (0.87 versus 0.73) in discriminating between FM and RApatients. Test-retest reliability of SREP sensitization was good in FM (intraclass correlations = 0.80), and moderate in RA (intraclass correlations = 0.68). CONCLUSIONS: SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared with a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.
Authors: Carmen M Galvez-Sánchez; Cristina Muñoz Ladrón de Guevara; Casandra I Montoro; María José Fernández-Serrano; Stefan Duschek; Gustavo A Reyes Del Paso Journal: PLoS One Date: 2018-08-01 Impact factor: 3.240
Authors: Carmen M Galvez-Sánchez; Pablo de la Coba; José M Colmenero; Gustavo A Reyes Del Paso; Stefan Duschek Journal: PLoS One Date: 2021-01-27 Impact factor: 3.240
Authors: Sofía López-Roig; Carmen Ecija; Cecilia Peñacoba; Sofía Ivorra; Ainara Nardi-Rodríguez; Oscar Lecuona; María Angeles Pastor-Mira Journal: Int J Environ Res Public Health Date: 2022-03-04 Impact factor: 3.390