Literature DB >> 29742542

Dynamic Current Focusing: A Novel Approach to Loudness Coding in Cochlear Implants.

Monique A M de Jong1, Jeroen J Briaire1, Johan H M Frijns1,2.   

Abstract

OBJECTIVES: In an attempt to improve spectral resolution and speech intelligibility, several current focusing methods have been proposed to increase spatial selectivity by decreasing intracochlear current spread. For example, tripolar stimulation administers current to a central electrode and uses the two flanking electrodes as the return pathway, creating a narrower intracochlear electrical field and hence increases spectral resolution when compared with monopolar (MP) stimulation. However, more current is required, and in some patients, specifically the ones with high electrode impedances, full loudness growth cannot be supported because of compliance limits. The present study describes and analyses a new loudness encoding approach that uses tripolar stimulation near threshold and gradually broadens the excitation (by decreasing compensation coefficient σ) to increase loudness without the need to increase overall current. It is hypothesized that this dynamic current focusing (DCF) strategy increases spatial selectivity, especially at lower loudness levels, while maintaining maximum selectivity at higher loudness levels, without reaching compliance limits.
DESIGN: Eleven adult cochlear implant recipients with postlingual hearing loss, with at least 9 months of experience with their HiRes90K implant, were selected to participate in this study. Baseline performance regarding speech intelligibility in noise (Dutch matrix sentence test), spectral ripple discrimination at 45 and 65 dB, and temporal modulation detection thresholds were assessed using their own clinical program, fitted on a Harmony processor. Subsequently, the DCF strategy was fitted on a research Harmony processor. Threshold levels were determined with σ = 0.8, which means 80% of current is returned to the flanking electrodes and the remaining 20% to the extracochlear ground electrode. Instead of increasing overall pulse magnitude, σ was decreased to determine most comfortable loudness. After 2 to 3 hr of adaptation to the research strategy, the same psychophysical measures were taken.
RESULTS: At 45 dB, average spectral ripple scores improved significantly from 2.4 ripples per octave with their clinical program to 3.74 ripples per octave with the DCF strategy (p = 0.016). Eight out of 11 participants had an improved spectral resolution at 65 dB. Nevertheless, no significant difference between DCF and MP was observed at higher presentation levels. Both speech-in-noise and temporal modulation detection thresholds were equal for MP and DCF strategies. Subjectively, 2 participants preferred the DCF strategy over their own clinical program, 2 preferred their own strategy, while the majority of the participants had no preference. Battery life was decreased and ranged from 1.5 to 4 hr.
CONCLUSIONS: The DCF strategy gives better spectral resolution, at lower loudness levels, but equal performance on speech tests. These outcomes warrant for a longer adaptation period to study long-term outcomes and evaluate if the outcomes in the ripple tests transfer to the speech scores. Further research, for example, with respect to fitting rules and reduction of power consumption, is necessary to make the DCF strategy suitable for routine clinical application.

Entities:  

Mesh:

Year:  2019        PMID: 29742542     DOI: 10.1097/AUD.0000000000000593

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  5 in total

1.  The effect of increased channel interaction on speech perception with cochlear implants.

Authors:  Tobias Goehring; Alan W Archer-Boyd; Julie G Arenberg; Robert P Carlyon
Journal:  Sci Rep       Date:  2021-05-17       Impact factor: 4.379

2.  Word Recognition and Frequency Selectivity in Cochlear Implant Simulation: Effect of Channel Interaction.

Authors:  Pierre-Antoine Cucis; Christian Berger-Vachon; Hung Thaï-Van; Ruben Hermann; Stéphane Gallego; Eric Truy
Journal:  J Clin Med       Date:  2021-02-10       Impact factor: 4.241

3.  Current Focusing to Reduce Channel Interaction for Distant Electrodes in Cochlear Implant Programs.

Authors:  Lindsay DeVries; Julie G Arenberg
Journal:  Trends Hear       Date:  2018 Jan-Dec       Impact factor: 3.293

4.  Investigating the Electrical Properties of Different Cochlear Implants.

Authors:  Nol Swaddiwudhipong; Chen Jiang; Thomas G Landry; Manohar Bance
Journal:  Otol Neurotol       Date:  2021-01       Impact factor: 2.619

5.  Using Spectral Blurring to Assess Effects of Channel Interaction on Speech-in-Noise Perception with Cochlear Implants.

Authors:  Tobias Goehring; Julie G Arenberg; Robert P Carlyon
Journal:  J Assoc Res Otolaryngol       Date:  2020-06-09
  5 in total