Literature DB >> 29739649

Desaturation times between dogs preoxygenated via face mask or flow-by technique before induction of anesthesia.

Barbara Ambros1, Maria Valentina Carrozzo2, Teela Jones2.   

Abstract

OBJECTIVE: To compare time to desaturation after induction of anesthesia following administration of oxygen via face mask or flow-by for 3 minutes. STUDY
DESIGN: Randomized crossover study. ANIMALS: A group of six healthy adult dogs weighing 15.0 ± 3.4 kg.
METHODS: Dogs were anesthetized twice separated by 14 days. Intramuscular administration of dexmedetomidine (4 μg kg-1), acepromazine (0.01 mg kg-1) and butorphanol (0.2 mg kg-1) provided sedation for percutaneous insertion of a catheter into the tracheal lumen. The tip was advanced to the thoracic inlet and position confirmed using fluoroscopy. Using a sample aspiration rate 200 mL minute-1, inspired (FIO2) and end-tidal oxygen (Fe'O2) were measured. Oxygen (100 mL kg-1 minute-1) was delivered into a circle delivery system and administered to the dog for 3 minutes via face mask or flow-by from the circle Y-piece 2.5 cm from the nares. Then, propofol was administered to induce anesthesia and apnea. A pulse oximeter (lingual probe) measured hemoglobin saturation (SpO2). At SpO2 90% (desaturation point), an endotracheal tube was inserted to allow administration of oxygen and artificial ventilation. Arterial blood and data were collected at baseline (before oxygen administration), 5 seconds after induction of anesthesia, and every 30 seconds until the desaturation point was reached. Data were analyzed using an unpaired and paired t test with (p < 0.05).
RESULTS: FIO2, Fe'O2 and PaO2 (mean ± standard deviation) were significantly higher after mask preoxygenation [89.7 ± 5.5%, 83.0 ± 7.6% and 394 ± 112 mmHg (52.4 ± 14.9 kPa)] compared with flow-by [30.0 ± 5.4%, 22.7 ± 3.8% and 133 ± 22 mmHg (17.7 ± 2.9 kPa)], respectively. Time to desaturation was significantly longer after mask treatment compared with flow-by (187 ± 67 versus 66 ± 17 seconds). CONCLUSIONS AND CLINICAL RELEVANCE: Mask preoxygenation provided longer time to desaturation compared with the flow-by technique tested. Crown
Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  anesthetic induction; dog; face mask; flow-by; preoxygenation

Mesh:

Substances:

Year:  2018        PMID: 29739649     DOI: 10.1016/j.vaa.2018.03.004

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  1 in total

1.  Oxygen delivery by mask improves the PaO2 of pregnant ewes during short term anaesthesia for caesarean delivery of preterm lambs.

Authors:  Gabrielle C Musk; Helen Kershaw; Matthew W Kemp
Journal:  Vet Anim Sci       Date:  2021-04-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.