Literature DB >> 29738945

Improved sensitivity and limit-of-detection of lateral flow devices using spatial constrictions of the flow-path.

Ioannis N Katis1, Peijun J W He2, Robert W Eason2, Collin L Sones2.   

Abstract

We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device. Crown
Copyright © 2018. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Increased sensitivity; Lateral flow devices; Photo-polymerisation

Mesh:

Substances:

Year:  2018        PMID: 29738945     DOI: 10.1016/j.bios.2018.05.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Double Competitive Immunodetection of Small Analyte: Realization for Highly Sensitive Lateral Flow Immunoassay of Chloramphenicol.

Authors:  Dmitriy V Sotnikov; Lyubov V Barshevskaya; Anastasia V Bartosh; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Biosensors (Basel)       Date:  2022-05-17

2.  A Critical Comparison between Flow-through and Lateral Flow Immunoassay Formats for Visual and Smartphone-Based Multiplex Allergen Detection.

Authors:  Georgina M S Ross; Gert Ij Salentijn; Michel W F Nielen
Journal:  Biosensors (Basel)       Date:  2019-12-12

Review 3.  Recent advances in sensitivity enhancement for lateral flow assay.

Authors:  Yulin Deng; Hao Jiang; Xiaoqiong Li; Xuefei Lv
Journal:  Mikrochim Acta       Date:  2021-10-13       Impact factor: 5.833

4.  A Polydopamine-Coated Gold Nanoparticles Quenching Quantum Dots-Based Dual-Readout Lateral Flow Immunoassay for Sensitive Detection of Carbendazim in Agriproducts.

Authors:  Xinxin Mao; Yulong Wang; Lan Jiang; Hanxiaoya Zhang; Yun Zhao; Pengyan Liu; Juanjuan Liu; Bruce D Hammock; Cunzheng Zhang
Journal:  Biosensors (Basel)       Date:  2022-01-29

Review 5.  Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials.

Authors:  Amadeo Sena-Torralba; Ruslan Álvarez-Diduk; Claudio Parolo; Andrew Piper; Arben Merkoçi
Journal:  Chem Rev       Date:  2022-09-06       Impact factor: 72.087

Review 6.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12
  6 in total