| Literature DB >> 29737037 |
Guadalupe García-Isla1, Andy Luis Olivares1, Etelvino Silva2, Marta Nuñez-Garcia1, Constantine Butakoff1, Damian Sanchez-Quintana3, Hernán G Morales4,5, Xavier Freixa6, Jérôme Noailly1, Tom De Potter2, Oscar Camara1.
Abstract
The left atrial appendage (LAA) is a complex and heterogeneous protruding structure of the left atrium (LA). In atrial fibrillation patients, it is the location where 90% of the thrombi are formed. However, the role of the LAA in thrombus formation is not fully known yet. The main goal of this work is to perform a sensitivity analysis to identify the most relevant LA and LAA morphological parameters in atrial blood flow dynamics. Simulations were run on synthetic ellipsoidal left atria models where different parameters were individually studied: pulmonary veins and mitral valve dimensions; LAA shape; and LA volume. Our computational analysis confirmed the relation between large LAA ostia, low blood flow velocities and thrombus formation. Additionally, we found that pulmonary vein configuration exerted a critical influence on LAA blood flow patterns. These findings contribute to a better understanding of the LAA and to support clinical decisions for atrial fibrillation patients.Entities:
Keywords: computational fluid dynamics; haemodynamics patterns; left atrial appendage morphology; sensitivity analysis; thrombus formation
Year: 2018 PMID: 29737037 DOI: 10.1002/cnm.3100
Source DB: PubMed Journal: Int J Numer Method Biomed Eng ISSN: 2040-7939 Impact factor: 2.747