The diagnostic and cellularity yield of reverse bevel versus fork-tip fine needle biopsy.

Mohamed M Abdelfatah1, Ahmed Hamed1, Nicholas J Koutlas1, F Zahra Aly2.   

Abstract

INTRODUCTION: Two new systems with a novel tip (Procore™ and SharkCore™) have been introduced for ultrasound-guided fine needle biopsy (US-FNB). Direct comparison of the diagnostic yield of these needles in the evaluation of pancreatic lesions is currently under investigation. This study aims to compare the diagnostic and cellular yields of the two needle systems.
METHODS: Consecutive patients with upper gastrointestinal lesions undergoing EUS-FNB using 22 gauge Procore™ (reverse bevel) or SharkCore™ (fork-tip) needles were included in the study. Cytological rapid on-site evaluation (ROSE) slides were scored on a numerical scale of diagnostic yield relative to the number of passes. Similarly, histology of biopsy material was assessed on diagnostic quality using a numeric score. The final diagnosis was based on resection specimens and/or follow-up of clinical and imaging data of the subject.
RESULTS: The diagnostic yield was similar between the fork-tip and reverse bevel needles (125/163; 77% vs 103/139;74% with P = .60). Sub-analysis for solid pancreatic masses demonstrated similar results (69/88; 78% vs. 83/107; 78% with P = .88). The fork-tip needle had a lower mean number of passes (2.5 vs 3.1; P = .04) and ROSE was utilized in significantly less cases than in the reverse bevel needle group (77% versus 98.3%).
CONCLUSIONS: Although we observed no difference in the diagnostic yield using either the fork-tip or the reverse bevel needle, the fork-tip needle had significantly better performance with regards to achieving more adequate cytologic specimen in fewer number of passes while at the same time requiring fewer episodes of ROSE.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  22 gauge; ROSE; endoscopic ultrasound; fine needle aspiration; pancreas; upper gastrointestinal tract

Mesh:

Year:  2018        PMID: 29737018     DOI: 10.1002/dc.23966

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  3 in total

1.  Diagnostic yield of Franseen and Fork-Tip biopsy needles for endoscopic ultrasound-guided tissue acquisition: a meta-analysis.

Authors:  Antonio Facciorusso; Valentina Del Prete; Vincenzo Rosario Buccino; Purvi Purohit; Puneet Setia; Nicola Muscatiello
Journal:  Endosc Int Open       Date:  2019-10-01

Review 2.  Therapeutic EUS: New tools, new devices, new applications.

Authors:  Barbara Braden; Vipin Gupta; Christoph Frank Dietrich
Journal:  Endosc Ultrasound       Date:  2019 Nov-Dec       Impact factor: 5.628

3.  Accuracy and clinical outcomes of pancreatic EUS-guided fine-needle biopsy in a consecutive series of 852 specimens.

Authors:  Mikkel Marschall Thomsen; Michael Hareskov Larsen; Tina Di Caterino; Gitte Hedegaard Jensen; Michael Bau Mortensen; Sönke Detlefsen
Journal:  Endosc Ultrasound       Date:  2022-06-08       Impact factor: 5.275

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.