| Literature DB >> 29736280 |
Izakson Alexander1,2, Sindawi Ahmad2, Ben Shachar Inbar2,3, Pikkel Joseph2,4.
Abstract
PURPOSE: Visual loss is a devastating perioperative complication that can result from elevated intraocular pressure (IOP). The Trendelenburg position during surgery increases IOP. The purpose of this study was to quantify IOP changes in patients undergoing laparoscopic hysterectomy, at different time points and body positions throughout the procedure, and to compare fluctuations of IOP during the perioperative period according to two fluid management protocols.Entities:
Year: 2018 PMID: 29736280 PMCID: PMC5874977 DOI: 10.1155/2018/1457851
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Details of the two fluid protocols.
| Time | Liberal fluid group | Restrictive fluid group |
|---|---|---|
| Before surgery | Fasting from midnight | Fasting from midnight |
| During surgery | 7 ml/kg/hr RL during first intraoperative hr, 5 ml/kg/hr for the subsequent hours | RL according to “4-2-1” 4 ml/kg/hr for first 10 kg (40 ml/hr) |
| After surgery (PACU) | 1.5 ml/kg/hr | “4-2-1” rule |
| After operation at the ward day of surgery | 1.5 ml/kg/hr RL | 1.5 ml/kg/hr RL |
| Postoperative day 1 | 1.5 ml/kg/hr RL, oral fluids | 1.5 ml/kg/hr RL, oral fluids |
| Postoperative day 2 | Oral fluids and solid food according to surgical allowance | Oral fluids and solid food according to surgical allowance |
RL: Ringer's lactate solution.
Figure 1Mean changes of IOP in the left eye (LE) for the two fluid management protocols. T4 and T5 refer to the time points at which patients were in the Trendelenburg position with CO2 insufflation of the abdomen. 1: liberal fluid protocol. 2: restrictive fluid protocol.
Figure 2Mean changes of IOP in the right eye (RE) for the two fluid management protocols. T4 and T5 refer to the time points at which patients were in the Trendelenburg position with CO2 insufflation of the abdomen. 1: liberal fluid protocol. 2: restrictive fluid protocol.
Figure 3For both fluid protocols, the linear correlation between IOP and MAP did not differ at different concentrations of fluid intake (correlation is significant at the 0.01 level; r = 0.275; p value = 0.001).
Figure 4IOP versus MAP for each fluid protocol. 1: liberal fluid protocol. 2: restrictive fluid protocol.
Figure 5The correlation between OPP and MAP for both protocols is significant at the 0.01 level (r = 0.871, p = 0.001). OPP = MAP-IOP.