Literature DB >> 29735479

Comparison of long-term clinical evolution in highly myopic eyes with vertical oval-shaped dome with or without untreated serous retinal detachment.

Antonio García-Ben1, Ignacio Garcia-Basterra2, Ana González-Gómez2, Isabel Baquero-Aranda2, María José Morillo-Sanchez2, Antonio Soler-García2, Jose Manuel García-Campos2.   

Abstract

BACKGROUND: To compare the long-term clinical evolution of highly myopic eyes with vertical oval-shaped dome associated with or without untreated serous retinal detachment.
METHODS: Twenty-eight patients with high myopia (40 eyes) with smooth macular elevations related to a vertical oval-shaped dome were recruited. Serous retinal detachment was investigated; 11 eyes had persistent submacular fluid (study group) and 29 eyes lacked submacular fluid (control group). All patients underwent complete ophthalmological examinations, including optical coherence tomography at baseline every 6 months for 2 years. Fluorescein angiographies were performed in cases with serous retinal detachment to rule out choroidal neovascularisation.
RESULTS: There were no statistical differences in baseline age, sex, spherical equivalence or axial length between the two groups. Serous retinal detachment always occurred at the top of the inward macular incurvation. Moreover, no statistically significant differences in mean best-corrected visual acuity were observed during the 24-month follow-up period in the study and control groups and between the two groups at all time points. The mean central foveal thickness was significantly higher in the study group at each visit (p=0.001, in all cases). At the final follow-up visit, complete resolution of the serous retinal detachment was achieved in 1 of the 11 study group's eyes.
CONCLUSIONS: Serous retinal detachment is a complication associated with vertical oval-shaped domes that seems to remain stable in terms of visual function over time without treatment. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  dome-shaped macula; high myopia; optical coherence tomography; serous retinal detachment; vertical oval-shaped dome

Mesh:

Year:  2018        PMID: 29735479     DOI: 10.1136/bjophthalmol-2018-311895

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  2 in total

1.  Factors associated with macular complications in highly myopic eyes with dome-shaped macular configuration.

Authors:  Mumin Hocaoglu; M Giray Ersoz; Isil Sayman Muslubas; Serra Arf; Murat Karacorlu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-04       Impact factor: 3.117

Review 2.  Dome-shaped maculopathy: a review.

Authors:  Mukesh Jain; Lingam Gopal; Tapas Ranjan Padhi
Journal:  Eye (Lond)       Date:  2021-04-19       Impact factor: 4.456

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.