Literature DB >> 29735136

Assessment of Coronal Spinal Alignment for Adult Spine Deformity Cases After Intraoperative T Square Shaped Use.

Swamy Kurra1, Umesh Metkar1, Henaku Yirenkyi1, Richard A Tallarico1, William F Lavelle2.   

Abstract

STUDY
DESIGN: Retrospectively reviewed surgeries between 2011 and 2015 of patients who underwent posterior spinal deformity instrumentation with constructs involving fusions to pelvis and encompassing at least five levels.
OBJECTIVE: Measure the radiographic outcomes of coronal malalignment (CM) after use of an intraoperative T square shaped instrument in posterior spinal deformity surgeries with at least five levels of fusion and extension to pelvis.
BACKGROUND: Neuromuscular children found to benefit from intraoperative T square technique to help achieve proper coronal spinal balance with extensive fusions. This intraoperative technique used in our posterior spine deformity instrumentation surgeries with the aforementioned parameters.
METHODS: There were 50 patients: n = 16 with intraoperative T square and n = 34 no-T square shaped device. Subgroups divided based on greater than 20 mm displacement and greater than 40 mm displacement of the C7 plumb line to the central sacral vertical line on either side in preoperative radiographs. We analyzed the demographics and the pre- and postoperative radiographic parameters of standing films: standing CM (displacement of C7 plumb line to central sacral vertical line), and major coronal Cobb angles in total sample and subgroups and compared T square shaped device with no-T square shaped device use by analysis of variance. A p value ≤.05 is statistically significant.
RESULTS: In the total sample, though postoperative CM mean was not statistically different, we observed greater CM corrections in patients where a T square shaped device was used (70%) versus no-T square shaped device used (18%). In >20 mm and >40 mm subgroups, the postoperative mean CM values were statistically lower for the patients where a T square shaped device was used, p = .016 and p = .003, respectively. Cobb corrections were statistically higher for T square shaped device use in both >20 mm and >40 mm subgroups, 68%, respectively.
CONCLUSION: The intraoperative T square shaped device technique had a positive effect on the amount of spine coronal malalignment correction after its use and for lumbar and thoracic coronal Cobb angles. LEVEL OF EVIDENCE: Level III.
Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adult posterior spinal deformity surgery; Cobb angle; Coronal malalignment; Coronal spinal alignment; T square shaped device

Mesh:

Year:  2018        PMID: 29735136     DOI: 10.1016/j.jspd.2017.10.012

Source DB:  PubMed          Journal:  Spine Deform        ISSN: 2212-134X


  2 in total

1.  A novel integrated global coronal aligner helps prevent post-operative standing coronal imbalance in adult spinal deformity patients fused to pelvis: technical notes and preliminary results.

Authors:  Jiandang Zhang; Pengfei Chi; Junyao Cheng; Zheng Wang
Journal:  BMC Musculoskelet Disord       Date:  2021-03-26       Impact factor: 2.362

2.  Risk Factors for Immediate Postoperative Coronal Imbalance in Degenerative Lumbar Scoliosis Patients Fused to Pelvis.

Authors:  Jiandang Zhang; Zheng Wang; Pengfei Chi
Journal:  Global Spine J       Date:  2020-04-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.