Inter- and Intraobserver Reliability of Pelvic Obliquity Measurement Methods in Patients With Cerebral Palsy.

M Wade Shrader1, Emily M Andrisevic2, Mohan V Belthur2, Gregory R White2, Carla Boan2, William Wood3.   

Abstract

STUDY
DESIGN: Retrospective, chart review.
OBJECTIVES: The identification and management of pelvic obliquity in neuromuscular scoliosis can be difficult; therefore, appropriate evaluation of this pathology is important. Variations in presentation have resulted in various methods of measurement, without a consensus or gold standard measurement. This study is the evaluation of reliability of five methods commonly used to determine pelvic obliquity in the frontal plane. SUMMARY OF BACKGROUND DATA: Previous studies have used five different methods (ie, the Maloney method, the O'Brien method, the Osebold method, the Allen and Ferguson method, and the Lindseth method) to determine pelvic obliquity in the frontal plane.
METHODS: Radiographic images of 50 patients with neuromuscular scoliosis involving the pelvic girdle were identified and evaluated by a team of 5 raters. Each rater was instructed to apply five commonly used methods of measuring pelvic obliquity. The same raters were asked to rate the same radiographs again after a minimum of one month. The interobserver reliability was assessed using the intraclass correlation coefficient (ICC) and the intraobserver analysis was assessed using the Pearson correlation. A rating greater than 0.8 was considered excellent reliability.
RESULTS: The Maloney method showing the highest interobserver reliability of ICC of 0.965 and 0.964. The Lindseth method had the lowest ICC, but all the methods were considered highly reliable by the rating classification system. The Maloney method also showed the highest intraobserver reliability, ranging from 0.845 to 0.962. The Allen and Ferguson method had the lowest intraobserver reliability.
CONCLUSIONS: Many of the methods tested had excellent reliability in this study, but our data suggest the Maloney method is the most reliable method of measuring pelvic obliquity on a frontal view radiograph. LEVEL OF EVIDENCE: Level III, retrospective, comparative study.
Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cerebral palsy; Pelvic obliquity; Radiograph; Scoliosis

Mesh:

Year:  2018        PMID: 29735134     DOI: 10.1016/j.jspd.2017.10.001

Source DB:  PubMed          Journal:  Spine Deform        ISSN: 2212-134X


  5 in total

1.  Restoring femoral medial offset could reduce pelvic obliquity following primary total hip arthroplasty, an observational study.

Authors:  Alireza Moharrami; Seyed Peyman Mirghaderi; Nima Hoseini-Zare; Mohammad Hasan Kaseb; Seyed Mir Mansour Moazen-Jamshidi; Ahmed Kareem Mansour; Seyed Mohammad Javad Mortazavi
Journal:  Int Orthop       Date:  2022-07-21       Impact factor: 3.479

2.  Pelvic fixation in surgical correction of neuromuscular scoliosis.

Authors:  Mazda Farshad; Sabrina Weber; José Miguel Spirig; Michael Betz; Samuel Haupt
Journal:  N Am Spine Soc J       Date:  2022-05-11

Review 3.  Spine deformities in patients with cerebral palsy; the role of the pelvis.

Authors:  Carol Hasler; Reinald Brunner; Alon Grundshtein; Dror Ovadia
Journal:  J Child Orthop       Date:  2020-02-01       Impact factor: 1.548

4.  The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis.

Authors:  Alexa J Karkenny; Lacey C Magee; Matthew R Landrum; Jason B Anari; David Spiegel; Keith Baldwin
Journal:  JB JS Open Access       Date:  2021-03-10

5.  The radiographic assessments of spino-pelvic compensation using IoT-based real-time ischial pressure adjustment.

Authors:  Moon-Jun Sohn; Haenghwa Lee; Byung-Jou Lee; Hae-Won Koo; Kwang Hyeon Kim; Sang-Won Yoon
Journal:  Medicine (Baltimore)       Date:  2022-02-04       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.