Literature DB >> 29734460

Diagnostic Accuracy of Fluoroscopy, Radiography, and Computed Tomography in Detecting Cement Leakage in Kyphoplasty.

Hans-Georg Palm1, Hans-Joachim Riesner1, Patricia Lang1, Madlen Haentzsch1, Benedikt Friemert1, Carsten Hackenbroch1.   

Abstract

PURPOSE: Cement leakage is a typical complication of kyphoplasty for vertebral fractures. It is unclear if cement application intraoperatively can be improved by using other techniques of visualization and which kind of postoperative imaging should be recommended to detect cement extravasation accurately.
OBJECTIVE: To compare the rates of cement leakage detected by intraoperative fluoroscopy, postoperative radiography, and postoperative computed tomography (CT) in a retrospective study. PATIENTS AND METHODS: The study included 78 patients (60 women and 18 men; 115 vertebral bodies) who were treated with two kinds of kyphoplasty. The patients underwent intraoperative fluoroscopy and postoperative radiography and CT. After surgery, the images were evaluated to compare cement leakage rates and locations in the three visualization techniques. Leakage locations were described as epidural, intradiskal, extravertebral, or intravascular.
RESULTS: Compared with CT, intraoperative fluoroscopy regularly detected intradiskal leakage (75%) but had a considerably lower sensitivity for visualizing epidural (21%), extravertebral (31%), and intravascular (51%) cement leakages. A comparison of radiography and CT showed that radiography had a high sensitivity for detecting intradiskal (82%) and intravascular (70%) cement extrusions but a lower sensitivity in identifying epidural (42%) and extravertebral (50%) leaks. Therefore, the CT scan overall was best in detecting location and accuracy.
CONCLUSION: CT detected more cement leaks than any of the other investigated techniques, especially epidural, extravertebral, and intravascular cement leakages. To achieve the best accuracy, only CT provides complete information. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29734460     DOI: 10.1055/s-0038-1641734

Source DB:  PubMed          Journal:  J Neurol Surg A Cent Eur Neurosurg        ISSN: 2193-6315            Impact factor:   1.268


  1 in total

1.  Influence of direct radiography in decision making during orthopaedic trauma surgery: A prospective study.

Authors:  Ibrahim Alper Yavuz; Utku Gurhan; Erman Ceyhan; Fatih Inci; Ozdamar Fuad Oken; Ahmet Ozgur Yildirim; Ozlem Ozkale Yavuz
Journal:  J Orthop       Date:  2022-10-07
  1 in total