Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

Mathieu Boudreau1, G Bruce Pike1,2.   

Abstract

PURPOSE: To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F).
METHODS: An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize for robustness against noise and B1 inaccuracies, the optimization condition was defined as the Cramér-Rao lower bound (CRLB) regularized by the B1 -sensitivity expression for the parameter of interest (F). The qMT protocols were iteratively optimized from an initial search space, with and without B1 regularization. Three 10-point qMT protocols (Uniform, CRLB, CRLB+B1 regularization) were compared using Monte Carlo simulations for a wide range of conditions (e.g., SNR, B1 inaccuracies, tissues).
RESULTS: The B1 -regularized CRLB optimization protocol resulted in the best robustness of F against B1 errors, for a wide range of SNR and for both white matter and gray matter tissues. For SNR = 100, this protocol resulted in errors of less than 1% in mean F values for B1 errors ranging between -10 and 20%, the range of B1 values typically observed in vivo in the human head at field strengths of 3 T and less. Both CRLB-optimized protocols resulted in the lowest σF values for all SNRs and did not increase in the presence of B1 inaccuracies.
CONCLUSION: This work demonstrates a regularized optimization approach for improving the robustness of auxiliary measurements (e.g., B1 ) sensitivity of qMT parameters, particularly the pool-size ratio (F). Predicting substantially less B1 sensitivity using protocols optimized with this method, B1 mapping could even be omitted for qMT studies primarily interested in F.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Mesh:

Year:  2018        PMID: 29733460     DOI: 10.1002/mrm.27337

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Scan-Rescan Repeatability and Impact of B0 and B1 Field Nonuniformity Corrections in Single-Point Whole-Brain Macromolecular Proton Fraction Mapping.

Authors:  Vasily L Yarnykh; Alena A Kisel; Marina Y Khodanovich
Journal:  J Magn Reson Imaging       Date:  2019-11-18       Impact factor: 4.813

2.  On the open-source landscape of PLOS Computational Biology.

Authors:  Mathieu Boudreau; Jean-Baptiste Poline; Pierre Bellec; Nikola Stikov
Journal:  PLoS Comput Biol       Date:  2021-02-11       Impact factor: 4.475

Review 3.  Macromolecular Proton Fraction as a Myelin Biomarker: Principles, Validation, and Applications.

Authors:  Alena A Kisel; Anna V Naumova; Vasily L Yarnykh
Journal:  Front Neurosci       Date:  2022-02-09       Impact factor: 5.152

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.