Literature DB >> 29732460

Evaluation of GPU-Based CT Reconstruction for Morbidly Obese Patients.

Rui Liu1, Mannudeep K Kalra2, Jiang Hsieh3, Hengyong Yu1.   

Abstract

The obese population is increasing in the United States. There have been modest improvements in scanner hardware and image processing to address some specific challenges associated with imaging of the morbidly obese patients. However, most legacy CT systems lack capabilities to provide sufficient delivery of image-based diagnosis in this increasing subset of population. One of the most common problems is the projection data truncation in CT imaging due to the massive girths of obese patients. In the past decade, it was proved that the image can be accurately and stably reconstructed from locally truncated projections if certain prior knowledge is known, and this technique is named interior tomogrpahy. To overcome the time-consuming issue of the iterative algorithms, we apply GPU techniques to speed up the reconstruction process. In this paper, we evaluate the GPU-based CT reconstruction algorithms (one analytic algorithm and one iterative reconstruction algorithm) for obese patients with both simulated and real clinical datasets. While the approximate analytic reconstruction algorithm outperforms the iterative reconstruction (IR) algorithm in terms of computational cost, the IR algorithm outperforms the analytic one in terms of image quality especially when the projection data is suffered from patient motion, which can happen when the obese patients are not able to hold a breath during the scan.

Entities:  

Keywords:  Analytic reconstruction; Clinical application; GPU speedup; Iterative reconstruction; Obese patient problem

Year:  2017        PMID: 29732460      PMCID: PMC5931393     

Source DB:  PubMed          Journal:  JSM Biomed Imaging Data Pap        ISSN: 2476-2040


  26 in total

1.  Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware.

Authors:  K Mueller; R Yagel
Journal:  IEEE Trans Med Imaging       Date:  2000-12       Impact factor: 10.048

2.  A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.

Authors:  Xiangyang Tang; Jiang Hsieh; Roy A Nilsen; Sandeep Dutta; Dmitry Samsonov; Akira Hagiwara
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

3.  Real-time 3D computed tomographic reconstruction using commodity graphics hardware.

Authors:  Fang Xu; Klaus Mueller
Journal:  Phys Med Biol       Date:  2007-05-17       Impact factor: 3.609

4.  Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.

Authors:  Marc Kachelriess; Michael Knaup; Olivier Bockenbach
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

5.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Effect of obesity on image quality: fifteen-year longitudinal study for evaluation of dictated radiology reports.

Authors:  Raul N Uppot; Dushyant V Sahani; Peter F Hahn; Mannudeep K Kalra; Sanjay S Saini; Peter R Mueller
Journal:  Radiology       Date:  2006-06-26       Impact factor: 11.105

7.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

8.  Obesity and medical imaging challenges.

Authors:  April Reynolds
Journal:  Radiol Technol       Date:  2011 Jan-Feb

9.  Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.

Authors:  E Watanabe; T Watanabe; S Manaka; Y Mayanagi; K Takakura
Journal:  Surg Neurol       Date:  1987-06

10.  An X-ray computed tomography imaging agent based on long-circulating bismuth sulphide nanoparticles.

Authors:  Oded Rabin; J Manuel Perez; Jan Grimm; Gregory Wojtkiewicz; Ralph Weissleder
Journal:  Nat Mater       Date:  2006-01-29       Impact factor: 43.841

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.