Literature DB >> 29730934

Development of an Integrated Syringe-Pump-Based Environmental-Water Analyzer ( iSEA) and Application of It for Fully Automated Real-Time Determination of Ammonium in Fresh Water.

Jian Ma1, Peicong Li1, Zhaoying Chen1, Kunning Lin1, Nengwang Chen1, Yiyong Jiang1, Jixin Chen1, Bangqin Huang1, Dongxing Yuan1.   

Abstract

The development of a multipurpose integrated syringe-pump-based environmental-water analyzer ( iSEA) and its application for spectrophotometric determination of ammonium is presented. The iSEA consists of a mini-syringe pump equipped with a selection valve and laboratory-programmed software written by LabVIEW. The chemistry is based on a modified indophenol method using o-phenylphenol. The effect of reagent concentrations and sample temperatures was evaluated. This fully automated analyzer had a detection limit of 0.12 μM with sample throughput of 12 h-1. Relative standard deviations at different concentrations (0-20 μM) were 0.23-3.36% ( n = 3-11) and 1.0% ( n = 144, in 24 h of continuous measurement, ∼5 μM). Calibration curves were linear ( R2 = 0.9998) over the range of 0-20 and 0-70 μM for the detection at 700 and 600 nm, respectively. The iSEA was applied in continuous real-time monitoring of ammonium variations in a river for 24 h and 14 days. A total of 1802 samples were measured, and only 0.4% was outlier data (≥3 sigma residuals). Measurements of reference materials and different aqueous samples ( n = 26) showed no significant difference between results obtained by reference and present methods. The system is compact (18 cm × 22 cm × 24 cm), portable (4.8 kg), and robust (high-resolution real-time monitoring in harsh environments) and consumes a small amount of chemicals (20-30 μL/run) and sample/standards (2.9 mL/run).

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29730934     DOI: 10.1021/acs.analchem.8b01490

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic Acid, Nitrate plus Nitrite in Seawater.

Authors:  Mahmoud Fatehy Altahan; Mario Esposito; Eric P Achterberg
Journal:  Sensors (Basel)       Date:  2022-05-03       Impact factor: 3.847

2.  The Automation Technique Lab-In-Syringe: A Practical Guide.

Authors:  Burkhard Horstkotte; Petr Solich
Journal:  Molecules       Date:  2020-04-01       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.