Literature DB >> 29728290

Posterior cornea and thickness changes after scleral lens wear in keratoconus patients.

Maria Serramito1, Carlos Carpena-Torres1, Jesús Carballo1, David Piñero2, Michael Lipson3, Gonzalo Carracedo4.   

Abstract

PURPOSE: To evaluate the changes in the corneal thickness, anterior chamber depth and posterior corneal curvature and aberrations after scleral lens wear in keratoconus patients with and without intrastromal corneal ring segments (ICRS).
METHODS: Twenty-six keratoconus subjects (36.95 ± 8.95 years) were evaluated after 8 h of scleral lens wear. The subjects were divided into two groups: those with ICRS (ICRS group) and without ICRS (KC group). The study variables evaluated before and immediately after scleral lens wear included corneal thickness evaluated in different quadrants, posterior corneal curvature at 2, 4, 6 and 8 mm of corneal diameter, posterior corneal aberrations for 4, 6 and 8 mm of pupil size and anterior chamber depth.
RESULTS: There was a statistically significant corneal thinning (p < 0.05) in the inferior region of the KC group and in the superior region of the ICRS group. No change (p > 0.05) in the anterior chamber depth was found. The KC group showed a steepening (p < 0.05) in the temporal quadrant and a flattening that mainly affected to the superior-nasal quadrant. The ICRS group showed a steepening (p < 0.05) that mainly affected to the superior-nasal quadrant. Regarding posterior corneal aberrations, only changes (p < 0.05) in Z4 for 8 mm and Z8 for 4 mm were found in the KC group.
CONCLUSIONS: Short-term scleral lens wear showed a thinning of the cornea and changes in the posterior corneal curvature affects different regions in keratoconus patients with and without ICRS.
Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anterior chamber; Corneal aberrations; Corneal curvature; Corneal thickness; Keratoconus; Scleral lenses

Mesh:

Year:  2018        PMID: 29728290     DOI: 10.1016/j.clae.2018.04.200

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Optical Impact of Corneal Clearance in Healthy Eyes Fitted with Scleral Contact Lenses: A Pilot Study.

Authors:  María Villa; Francisco Cavas; David P Piñero
Journal:  J Clin Med       Date:  2022-06-14       Impact factor: 4.964

Review 2.  How Can We Best Measure the Performance of Scleral Lenses? Current Insights.

Authors:  Rute J Macedo-de-Araújo; Daddi Fadel; Melissa Barnett
Journal:  Clin Optom (Auckl)       Date:  2022-04-07

3.  Characterization and prediction of the clinical result with a specific model of mini-scleral contact lens in corneas with keratoconus.

Authors:  Abdelkader Sidi Mohamed Hamida; García-Barchín Marta; Ruiz-Fortes Pedro; David P Piñero