Literature DB >> 29726406

A novel approach for quantitative harmonization in PET.

M Namías1, T Bradshaw, V O Menezes, M A D Machado, R Jeraj.   

Abstract

Positron emission tomography (PET) imaging allows for measurement of activity concentrations of a given radiotracer in vivo. The quantitative capabilities of PET imaging are particularly important in the context of monitoring response to treatment, where quantitative changes in tracer uptake could be used as a biomarker of treatment response. Reconstruction algorithms and settings have a significant impact on PET quantification. In this work we introduce a novel harmonization methodology requiring only a simple cylindrical phantom and show that it can match the performance of more complex harmonization approaches based on phantoms with spherical inserts. Resolution and noise measurements from cylindrical phantoms are used to simulate the spherical inserts from NEMA image quality phantoms. An optimization algorithm was used to find the optimal smoothing filters for the simulated NEMA phantom images to identify those that best harmonized the PET scanners. Our methodology was tested on seven different PET models from two manufacturers installed at five institutions. Our methodology is able to predict contrast recovery coefficients (CRCs) from NEMA phantoms with errors within  ±5.2% for CRCmax and  ±3.7% for CRCmean (limits of agreement  =  95%). After applying the proposed harmonization protocol, all the CRC values were within the tolerances from EANM. Quantitative harmonization in compliance with the EARL FDG-PET/CT accreditation program is achieved in a simpler way, without the need of NEMA phantoms. This may lead to simplified scanner harmonization workflows more accessible to smaller institutions.

Mesh:

Year:  2018        PMID: 29726406     DOI: 10.1088/1361-6560/aabb5f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  FDG PET/CT for Assessment of Immune Therapy: Opportunities and Understanding Pitfalls.

Authors:  Steve Y Cho; Daniel T Huff; Robert Jeraj; Mark R Albertini
Journal:  Semin Nucl Med       Date:  2020-06-28       Impact factor: 4.446

Review 2.  Simultaneous PET/MRI: The future gold standard for characterizing motor neuron disease-A clinico-radiological and neuroscientific perspective.

Authors:  Freimut D Juengling; Frank Wuest; Sanjay Kalra; Federica Agosta; Ralf Schirrmacher; Alexander Thiel; Wolfgang Thaiss; Hans-Peter Müller; Jan Kassubek
Journal:  Front Neurol       Date:  2022-08-17       Impact factor: 4.086

3.  Striatal D1 and D2 receptor availability are selectively associated with eye-blink rates after methylphenidate treatment.

Authors:  Şükrü B Demiral; Peter Manza; Erin Biesecker; Corinde Wiers; Ehsan Shokri-Kojori; Katherine McPherson; Evan Dennis; Allison Johnson; Dardo Tomasi; Gene-Jack Wang; Nora D Volkow
Journal:  Commun Biol       Date:  2022-09-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.