Literature DB >> 29726270

Complications of cataract surgery in eyes filled with silicone oil.

Piotr Kanclerz1, Andrzej Grzybowski2,3, Stephen G Schwartz4, Paweł Lipowski1.   

Abstract

INTRODUCTION: The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil.
METHODS: This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal.
RESULTS: In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed.
CONCLUSIONS: In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

Entities:  

Keywords:  Cataract; intraocular lens implantation; phacoemulsification; silicone oil

Mesh:

Substances:

Year:  2018        PMID: 29726270     DOI: 10.1177/1120672117753700

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Trocar opening: silicone oil removal with phacoemulsification and intraocular lens implantation.

Authors:  Xu Zhang; Ya-Jie Pan; Zheng-Yu Song
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

2.  Intraoperative Posterior Chamber Irrigation to Enhance Vitreous Cavity Support during Phacoemulsification Cataract Surgery after Vitrectomy.

Authors:  Jiao Lyu; Peiquan Zhao
Journal:  J Ophthalmol       Date:  2020-02-17       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.