Focused ultrasound with microbubbles induces sterile inflammatory response proportional to the blood brain barrier opening: Attention to experimental conditions.

Zsofia I Kovacs1, Scott R Burks1, Joseph A Frank1,2.   

Abstract

This editorial highlights the findings of McMahon [1] and demonstrates the need for careful attention to experimental conditions that influence microbubble concentration and pharmacokinetics contributed to focused ultrasound-induced blood brain barrier opening and sterile inflammation.

Entities:  

Mesh:

Year:  2018        PMID: 29722362      PMCID: PMC5928885          DOI: 10.7150/thno.24181

Source DB:  PubMed          Journal:  Theranostics        ISSN: 1838-7640            Impact factor:   11.556


The blood-brain barrier (BBB) maintains homeostasis, preventing the passage of toxins and cells into the brain that could induce inflammation and damage the surrounding elements of the neurovascular unit (NVU). Focused ultrasound (FUS) coupled with intravenous infusion of microbubbles (MB) can open the blood brain barrier and allow leakage of neurotherapeutics and plasma proteins into the parenchyma that can activate astrocytes and microglia 2. Pulsed focused ultrasound (pFUS) induces stable MB oscillations, which radiate pressure waves on and through the NVU. Either stable oscillations, or possibly intertial caviation, could alter the parenchymal microenvironment to increase expression of the cytokines, chemokines, trophic factors (CCTF), and cell adhesion molecules (CAM) observed in a sterile inflammatory response (SIR) 2. Transient SIR can both cause damage and stimulate repair mechanisms in the parenchyma 3, 4. pFUS+MB increases interferon-γ expression within the parenchyma by stimulating a local immune response within the targeted parenchyma 2 and this cytokine can stimulate an innate immune response aiding in the clearance of amyloid plaques in Alzheimer's disease (AD) models 5, 6. McMahon 1 reported that pFUS+MB-induced BBB disruption (BBBD) increased mRNA associated with inflammatory pathways involving nuclear factor kappa-light-chain-enhancer of activated B cells (NFκB) in brain obtained at 6 h post sonication, and that the SIR magnitude depended on the MB dose. Coupling pFUS with the US contrast agent Definity® at 10 µL/kg did not significantly elevate transcriptomic constituents of NFκB pathways, resulting in significantly less (p<0.01) signal intensity (SI) changes on gadolinium (Gd)-T1 weighted (w) images when compared to pFUS+Definity® at 100 µL/kg when the sonication peak negative pressure (PNP) was controlled by passive cavitation detection (PCD). pFUS+Definity® at 100 µL/kg resulted in a SIR evidenced by increasing mRNA expression of pro-inflammatory factors, larger SI changes that were homogenous in appearance, and the appearance of hypointense voxels on T2*w imaging 4 h post-sonication that were consistent with parenchymal damage. pFUS+Definity® at 100 µL/kg using PCD feedback did result in an inflammatory response with transcriptomic elevations in Ccl5, Faslg, Tnf, Il1b and Icam1 presumably in the absence of inertial cavitation. A linear correlation was observed between transcriptomic responses to pFUS+MB-induced BBBD and SI changes on MRI. However, the changes in SI and mRNA expression following pFUS+Definity® resulted in correlations with R2 ranging from 0.693 to 0.386 (depending on the CCTF), implying that between approximately 31% to 62% of the mRNA expression variability is unrelated to SI changes. The mRNA encoding for a range of IL1b, IL1a, and TNF associated with SIR had <42% of their variability accounted for based on SI alone, leaving other factors contributing to changes in SI unaccounted for 1. A lack of transcriptomic changes does not necessarily indicate unaltered protein expression since cells contain baseline quantities of mRNA available for protein translation without transcribing new mRNA. It is also possible that transcriptomic responses consistent with activated NFκB pathways to pFUS+Definity® at 10 µL/kg would have been observed if tissue sampling had been performed at other time points 2. These observations underscore the vital need to address questions regarding pFUS+MB-induced BBBD relating to MRI SI changes: 1) What magnitude of SI changes on Gd-T1w MRI precisely define BBBD? 2) How does the magnitude of SI changes following pFUS+MB predict adequate parenchymal delivery of neurotherapeutics or stimulation of molecular and or immune responses? McMahon attempted to replicate parts of a previous study by Kovacs 2, which used a pFUS peak negative pressure of 0.3 MPa (in water) at a transducer frequency of 589 kHz (translating to a mechanical index of 0.39)—below the reported limits of BBBD with erythrocyte extravasation 7 that induced a SIR in the area of BBBD. Important differences between the two studies lead to some overstating of the data in 1. McMahon attributes the SIR in Kovacs 2 to the fact that the OptisonTM MB dose (500 µL/kg) was 10-fold higher than the clinical dose and thus comparable to Definity® at 100 µL/kg (10-fold higher than its clinical US imaging dose). This relationship may not hold true for pFUS+MB induced BBBD. The two MB preparations are different in size, dispersity, and concentration (Definity®=1.2×1010 MB/mL, OptisonTM=5-8×108 MB/mL), which may affect their ability to open the BBB. Differences in total numbers of MB infused, infusion rates (IR), oxygenation states, and number of targets influence BBBD may alter the downstream parenchymal molecular responses. Kovacs infused OptisonTM (5-8×107 MB) at 100 µL/min over 1 min starting 30 s before sonication in rats inhaling 100% O2 that resulted in homogeneous BBBD over 9 focal spots based on Gd-T1w images 2. McMahon 1 infused Definity® diluted in saline at 10 or 100 µL/kg (1.2×108 MB/kg or 1.2×109 MB/kg, respectively) at 120 µL/min in rats on medical air (21% O2) sonicating at various PNP in one focal area. The intravascular half-life (T1/2) of both MBs is 1.3 min in air and 0.72 min on 100% O2 8-10. MBs are eliminated through the lungs and plasma concentration depends on the initial dose, IR, T1/2, and oxygenation status. Figure contains the equations and graphs from pharmacokinetic modeling (http://www.gatewaycoalition.org/files/hidden/deliv/ch3/3_5f.htm) of Definity® at 100 µL/kg, 20 µL/kg, and 10 µL/kg (air), IR=120 µL/min and OptisonTM at 500 µL/kg on air or 100% O2, IR=100 µL/min, all with 120 s of pFUS 1, 2. The Definity® dose of 20 µL/kg is based on a previous report 11. During the total FUS “on” time, the area under the curve (AUC) was 2.63×107 MB/kg for Definity® at 100 µL/kg on air. This was >8.4× greater than OptisonTM at 0.25-0.4×109 MB/kg (500 µL/kg) while inhaling 100% O2. Kovacs' MB dosing and pFUS protocol resulted in essentially no difference in AUC as Definity® at 10 µL/kg, underscoring the importance of IR and inhaled O2 2. The AUC calculations assumed fixed FUS pressures because the data presented by McMahon 1 do not allow determination of at which US burst number (i.e., time after initiating pFUS) stable cavitation would be detected. However, we can determine that AUC differences between constant or ramped pressures are negligible. McMahon 1 states that PNP was initially set at 0.128 MPa and ramped up to a mean of 0.192 MPa (0.064 MPa difference). Increasing by 0.008 MPa/cycle means that 0.192 MPa would be achieved by the 9th pulse. If we generously assume that no cavitation whatsoever occured during the first 8 pulses and remove those data points from the integration, the AUC values only change by <1% (2.63 vs. 2.61 for 100 µL/kg; 0.300 vs. 0.298 for 10 µL/kg). Of course, in reality, stable cavitation likely begins before the transducer reaches an inertial cavitation threshold. The modeling demonstrates that approaches to MB dosing demand at least quantifying circulating MB as discrete cavitation nuclei. It is clearly insufficient to simply adjust volumes of solution when dealing with different formulations. MB dosing by gas volume/kg correlates with BBBD and represents an alternative to liquid-volume-based dosing. MB size affects physical interactions with pFUS, making certain diameters better BBBD agents at a given frequency 12. Moreover, vascular heterogeneity will give different vessel types varying susceptibility to BBBD for disperse MB sizes. We agree with McMahon's findings that SIR will be proportional to MB dose on some level, but the picture is extremely complex. For pFUS+MB to emerge as a viable therapeutic option will require: 1) quantitative imaging standards that define adequate BBBD (i.e., MRI parameters and findings); 2) validated therapeutic and molecular/immunogical outcomes; and 3) the understanding of how the magnitude of BBBD is influenced by MB number, size, dispersity, IR and clearance. There are wide ranges of MRI parameters that can be manipulated to increase the conspicuity of BBBD following sonication, which also need standardization. Defining the infused MB concentration, IR and appropriate pFUS parameters used when canvassing brain pathologies, while investigating safety and the specific value of pFUS+MB to induce a SIR are necessary in stimulating an immune response. There are several reports that pFUS+Definity® at higher doses (20-80 µL/kg) was needed to open the BBB and clear amyloid plaques in mouse AD models 13-15. In the canine model of aging 16, pFUS with PCD feedback was coupled with an infusion of Definity® at 20 µL/kg. Although BBB opening was detected on Gd-T1w MRI, the clearance of amyloid plaques did not reach significance for the entire cohort possibly due to the small sample size. An SIR following pFUS+MB BBBD would be likely to occur with a Definity® dose ≥20 µL/kg compared to Definity® at 10 µL/kg used by McMahon 1. Indeed, an SIR that includes elevation in CCTF and CAM could be important to initiate an immune response that would help clear amyloid plaques 5, 6. If the minimal SIR profile observed by McMahon at 10 µL/kg 1 was induced in the transgenic AD mouse, there is a high possibility that little changes to pathology would be observed. Noninvasive image guided pFUS+MB opening of the BBB does hold potential compared to other invasive techniques 17, but still requires standardized parameters for US, MB dosing, IR, and MRI protocols. This leaves subsequent studies that investigate biology and therapeutic effectiveness sometimes difficult to interpret and underscores the importance of using acoustic emissions to calibrate PNP, which widens the safety window of pFUS+MB and improves consistency in BBBD.
  17 in total

Review 1.  Strategies to advance translational research into brain barriers.

Authors:  Edward Neuwelt; N Joan Abbott; Lauren Abrey; William A Banks; Brian Blakley; Thomas Davis; Britta Engelhardt; Paula Grammas; Maiken Nedergaard; John Nutt; William Pardridge; Gary A Rosenberg; Quentin Smith; Lester R Drewes
Journal:  Lancet Neurol       Date:  2008-01       Impact factor: 44.182

2.  Microbubble-size dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo.

Authors:  James J Choi; Jameel A Feshitan; Babak Baseri; Shougang Wang; Yao-Sheng Tung; Mark A Borden; Elisa E Konofagou
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-20       Impact factor: 4.538

Review 3.  Dealing with Danger in the CNS: The Response of the Immune System to Injury.

Authors:  Sachin P Gadani; James T Walsh; John R Lukens; Jonathan Kipnis
Journal:  Neuron       Date:  2015-07-01       Impact factor: 17.173

4.  The Effects of Oxygen on Ultrasound-Induced Blood-Brain Barrier Disruption in Mice.

Authors:  Nathan McDannold; Yongzhi Zhang; Natalia Vykhodtseva
Journal:  Ultrasound Med Biol       Date:  2016-10-24       Impact factor: 2.998

5.  Effect of anesthesia carrier gas on in vivo circulation times of ultrasound microbubble contrast agents in rats.

Authors:  Lee Mullin; Ryan Gessner; James Kwan; Mehmet Kaya; Mark A Borden; Paul A Dayton
Journal:  Contrast Media Mol Imaging       Date:  2011-01-19       Impact factor: 3.161

6.  Amyloid-β plaque reduction, endogenous antibody delivery and glial activation by brain-targeted, transcranial focused ultrasound.

Authors:  Jessica F Jordão; Emmanuel Thévenot; Kelly Markham-Coultes; Tiffany Scarcelli; Ying-Qi Weng; Kristiana Xhima; Meaghan O'Reilly; Yuexi Huang; Joanne McLaurin; Kullervo Hynynen; Isabelle Aubert
Journal:  Exp Neurol       Date:  2013-05-21       Impact factor: 5.330

7.  Investigating the efficacy of a combination Aβ-targeted treatment in a mouse model of Alzheimer's disease.

Authors:  Mingzhe Liu; Stefan Jevtic; Kelly Markham-Coultes; Nicholas P K Ellens; Meaghan A O'Reilly; Kullervo Hynynen; Isabelle Aubert; JoAnne McLaurin
Journal:  Brain Res       Date:  2017-10-21       Impact factor: 3.252

Review 8.  Rational modulation of the innate immune system for neuroprotection in ischemic stroke.

Authors:  Diana Amantea; Giuseppe Micieli; Cristina Tassorelli; María I Cuartero; Iván Ballesteros; Michelangelo Certo; María A Moro; Ignacio Lizasoain; Giacinto Bagetta
Journal:  Front Neurosci       Date:  2015-04-29       Impact factor: 4.677

9.  Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging.

Authors:  Po-Chun Chu; Wen-Yen Chai; Chih-Hung Tsai; Shih-Tsung Kang; Chih-Kuang Yeh; Hao-Li Liu
Journal:  Sci Rep       Date:  2016-09-15       Impact factor: 4.379

10.  Investigation of the Safety of Focused Ultrasound-Induced Blood-Brain Barrier Opening in a Natural Canine Model of Aging.

Authors:  Meaghan Anne O'Reilly; Ryan Matthew Jones; Edward Barrett; Anthony Schwab; Elizabeth Head; Kullervo Hynynen
Journal:  Theranostics       Date:  2017-08-22       Impact factor: 11.556

View more
  25 in total

Review 1.  Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound.

Authors:  Scott Schoen; M Sait Kilinc; Hohyun Lee; Yutong Guo; F Levent Degertekin; Graeme F Woodworth; Costas Arvanitis
Journal:  Adv Drug Deliv Rev       Date:  2021-11-18       Impact factor: 15.470

Review 2.  The roles of thermal and mechanical stress in focused ultrasound-mediated immunomodulation and immunotherapy for central nervous system tumors.

Authors:  Chulyong Kim; Michael Lim; Graeme F Woodworth; Costas D Arvanitis
Journal:  J Neurooncol       Date:  2022-03-02       Impact factor: 4.506

3.  Blood-brain barrier opening by intracarotid artery hyperosmolar mannitol induces sterile inflammatory and innate immune responses.

Authors:  Scott R Burks; Cymon N Kersch; Jaclyn A Witko; Michael A Pagel; Maggie Sundby; Leslie L Muldoon; Edward A Neuwelt; Joseph A Frank
Journal:  Proc Natl Acad Sci U S A       Date:  2021-05-04       Impact factor: 11.205

4.  Transcriptomic response of brain tissue to focused ultrasound-mediated blood-brain barrier disruption depends strongly on anesthesia.

Authors:  Alexander S Mathew; Catherine M Gorick; E Andrew Thim; William J Garrison; Alexander L Klibanov; G Wilson Miller; Natasha D Sheybani; Richard J Price
Journal:  Bioeng Transl Med       Date:  2020-11-24

Review 5.  Secondary effects on brain physiology caused by focused ultrasound-mediated disruption of the blood-brain barrier.

Authors:  Nick Todd; Cleide Angolano; Christiane Ferran; Anna Devor; David Borsook; Nathan McDannold
Journal:  J Control Release       Date:  2020-05-26       Impact factor: 11.467

6.  Safety evaluation of a clinical focused ultrasound system for neuronavigation guided blood-brain barrier opening in non-human primates.

Authors:  Antonios N Pouliopoulos; Nancy Kwon; Greg Jensen; Anna Meaney; Yusuke Niimi; Mark T Burgess; Robin Ji; Alicia J McLuckie; Fabian A Munoz; Hermes A S Kamimura; Andrew F Teich; Vincent P Ferrera; Elisa E Konofagou
Journal:  Sci Rep       Date:  2021-07-22       Impact factor: 4.379

7.  Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening.

Authors:  Robin Ji; Maria E Karakatsani; Mark Burgess; Morgan Smith; Maria F Murillo; Elisa E Konofagou
Journal:  J Control Release       Date:  2021-07-27       Impact factor: 11.467

8.  Reply to Kovacs et al.: Concerning acute inflammatory response following focused ultrasound and microbubbles in the brain.

Authors:  Dallan McMahon; Kullervo Hynynen
Journal:  Theranostics       Date:  2018-03-08       Impact factor: 11.556

9.  MRI and histological evaluation of pulsed focused ultrasound and microbubbles treatment effects in the brain.

Authors:  Zsofia I Kovacs; Tsang-Wei Tu; Maggie Sundby; Farhan Qureshi; Bobbi K Lewis; Neekita Jikaria; Scott R Burks; Joseph A Frank
Journal:  Theranostics       Date:  2018-09-09       Impact factor: 11.556

Review 10.  Blood-brain barrier opening with low intensity pulsed ultrasound for immune modulation and immune therapeutic delivery to CNS tumors.

Authors:  Kevin Beccaria; Aria Sabbagh; John de Groot; Michael Canney; Alexandre Carpentier; Amy B Heimberger
Journal:  J Neurooncol       Date:  2020-02-28       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.