| Literature DB >> 29720144 |
Emmanuel Appiah-Brempong1, Muriel J Harris2, Samuel Newton3, Gabriel Gulis4.
Abstract
BACKGROUND: The crucial role of adequate water, sanitation and hygiene (WASH) facilities in influencing children's handwashing behaviour is widely reported. Report from UNICEF indicates a dearth of adequate data on WASH facilities in schools, especially in the developing world. This study sought to contribute to building the evidence-base on school hygiene facilities in Ghana. The study further explored for possible associations and differences between key variables within the context of school water, sanitation and hygiene.Entities:
Keywords: Facilities; Functional; Hygiene; School; Water
Mesh:
Year: 2018 PMID: 29720144 PMCID: PMC5930960 DOI: 10.1186/s12889-018-5491-9
Source DB: PubMed Journal: BMC Public Health ISSN: 1471-2458 Impact factor: 3.295
School Selection
| ID | EDUCATIONAL CIRCUIT | POPULATION SIZE OF CIRCUIT | ESTIMATED NO. OF SCHOOLS REQUIRED |
|---|---|---|---|
| A | Achinakrom | 6 | 3 |
| B | Bomfa | 8 | 4 |
| C | Ejisu | 11 | 5 |
| D | Fumesua | 5 | 2 |
| E | Kubease | 8 | 4 |
| F | Kwaso | 9 | 4 |
| G | New Koforidua | 6 | 3 |
| H | Ofoase | 5 | 2 |
| I | Juaben | 14 | 6 |
| J | Tikrom | 8 | 4 |
| TOTAL | 80 | 37 | |
Source: Developed based on a list obtained from the EJM Education Directorate, 2016
Proportion of Schools with Specific Facilities
| S/N | Item | Number of Schools | Percentage (%) |
|---|---|---|---|
| A | Functionalb water point/facility | 6 | 16 |
| B | Functionalb water reservoir | 4 | 11 |
| C | Soap | 25 | 68 |
| D | Tap bucket (veronica bucket) | 13 | 36 |
| E | Shared/communal aHW receptacle | 12 | 33 |
| F | Receptacle (for waste water) | 11 | 31 |
| G | Paper/tissue towel | 0 | 0 |
| H | Shared cotton towel/napkin | 9 | 24 |
| I | Functional handwashing station | 6 | 16 |
| J | Functional toilet facility | 21 | 56 |
| Financial Provision for HW Facilities | |||
| K | Financial Provision for facilities | 10 | 27 |
| L | Source of funds | ||
| o Capitation grant | 1 | 6 | |
| o Internally Generated | 9 | 94 | |
Source: Field Survey, 2017 aHW-Handwashing bFacility was usable on the day of observation
A Scalogram Model on Schools and Functional Facilities
| School Identifier | Student Enrolment M(SD) = 153(81.9) | Existing Functional Facilities | Total no. of facilities | Centrality Indices | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Water Point | Hand-washing Station | Water Reservoir | Tap Bucket | Soap | Receptacle (waste water) | Toilet | Budget-Water Supply | ||||
| 0037 | 309 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 7 | 84.8 |
| 0027 | 198 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 0 | 6 | 74.8 |
| 0031 | 84 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 7 | 68.8 |
| 0023 | 178 | 1 | 1 | 0 | 1 | 1 | 0 | 1 | 1 | 6 | 59.8 |
| 0036 | 177 | 0 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 6 | 52.1 |
| 0028 | 201 | 0 | 0 | 1 | 0 | 1 | 1 | 1 | 0 | 4 | 42.7 |
| 0003 | 99 | 1 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 4 | 38.4 |
| 0015 | 46 | 1 | 1 | 0 | 0 | 1 | 0 | 0 | 0 | 3 | 37.4 |
| 0026 | 144 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 5 | 35.4 |
| 0029 | 258 | 0 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 3 | 33.7 |
| 0010 | 108 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 0 | 4 | 24.7 |
| 0001 | 119 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 1 | 3 | 23 |
| 0011 | 142 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 0 | 3 | 20.7 |
| 0025 | 103 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 1 | 3 | 18.7 |
| 0006 | 157 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 3 | 17.7 |
| 0008 | 98 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 2 | 17.7 |
| 0030 | 92 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 3 | 17.7 |
| 0034 | 180 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 3 | 17.7 |
| 0020 | 112 | 0 | 0 | 0 | 1 | 1 | 0 | 1 | 0 | 3 | 16.4 |
| 0032 | 50 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 0 | 2 | 13 |
| 0035 | 75 | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 0 | 2 | 12.4 |
| 0024 | 196 | 0 | 0 | 0 | 1 | 1 | 0 | 0 | 0 | 2 | 11.7 |
| 0004 | 100 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 10 |
| 0005 | 205 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 0 | 2 | 8.7 |
| 0017 | 227 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 0 | 2 | 8.7 |
| 0022 | 106 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 0 | 2 | 8.7 |
| 0007 | 296 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 4.7 |
| 0018 | 163 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 4.7 |
| 0033 | 334 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 4.7 |
| 0014 | 48 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 4.0 |
| 0021 | 134 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 4.0 |
| 0002 | 98 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| 0009 | 72 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| 0012 | 119 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| 0013 | 119 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| 0016 | 394 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| 0019 | 130 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0 |
| Total number of facilities | 6 | 6 | 4 | 13 | 25 | 11 | 21 | 10 | |||
| Assumed centrality | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |||
| Weight | 16.7 | 16.7 | 25 | 7.7 | 4 | 9.0 | 4.7 | 10 | |||
Source: Author’s Construct, 2017
Differences in Proportions and Means
| Student Enrolment | ||
|---|---|---|
| Response Variables | Mean(SD) | |
| Functional Toilet Facility | 0.04 | |
| - Exist | 177(76) | |
| - Does not exist | 123(82) | |
| Functional HWS* | 0.69 | |
| - Exist | 165(92) | |
| - Does not exist | 150(81) | |
| Functional HWS | ||
| Explanatory Variables | Cramer’s V | |
| Functional Water facility | 0.00 | 0.80 |
| Functional Toilet facility | 0.16 | – |
| Financial Provision for WS+ | 0.03 | 0.39 |
| Two-Sample Proportion Test | ||
| Proportion (95% CI) | ||
| Functional Water facility | −4.87 (0.00) | |
| - Within School | 0.83 (0.54–1.13) | |
| - Outside School | 0.03 (−0.03–0.10) | |
| Financial Provision for water supply | −2.38 (0.02) | |
| - Exist | 0.40 (0.10–0 .70) | |
| - Does not exist | 0.07 (− 0.02–0.17) | |
*HWS-Handwashing station +WS-Water supply