Literature DB >> 29714041

A microfluidic glucose sensor incorporating a novel thread-based electrode system.

Michelle Gaines1, Maria Jose Gonzalez-Guerrero1, Kathryn Uchida1, Frank A Gomez1.   

Abstract

An electrochemical sensor for the detection of glucose using thread-based electrodes and fabric is described. This device is relatively simple to fabricate and can be used for multiple readings after washing with ethanol. The fabrication of the chip consisted of two steps. First, three thread-based electrodes (reference, working, and counter) were fabricated by painting pieces of nylon thread with either layered silver ink and carbon ink or silver/silver chloride ink. The threads were then woven into a fabric chip with a beeswax barrier molded around the edges in order to prevent leaks from the tested solutions. A thread-based working electrode consisting of one layer of silver underneath two layers of carbon was selected to fabricate the final sensor system. Using the chip, a PBS solution containing glucose oxidase (GOx) (10 mg/mL), potassium ferricyanide (K3 [Fe(CN)6 ]) (10 mg/mL) as mediator, and different concentrations of glucose (0-25 mM), was measured by cyclic voltammetry (CV). It was found that the current output from the oxidation of glucose was proportional to the glucose concentrations. This thread-based electrode system is a viable sensor platform for detecting glucose in the physiological range.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Diagnostic device; Electrochemical sensor; Glucose; Point-of-care

Mesh:

Substances:

Year:  2018        PMID: 29714041     DOI: 10.1002/elps.201800010

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

Review 1.  Recent advances in thread-based microfluidics for diagnostic applications.

Authors:  Xuan Weng; Yuejun Kang; Qian Guo; Bei Peng; Hai Jiang
Journal:  Biosens Bioelectron       Date:  2019-03-08       Impact factor: 10.618

Review 2.  Paper and thread as media for the frugal detection of urinary tract infections (UTIs).

Authors:  Amrutha Hasandka; Ankita Ramchandran Singh; Anusha Prabhu; Hardik Ramesh Singhal; M S Giri Nandagopal; Naresh Kumar Mani
Journal:  Anal Bioanal Chem       Date:  2021-10-19       Impact factor: 4.142

3.  Cord-Based Microfluidic Chips as A Platform for ELISA and Glucose Assays.

Authors:  Jenny Elomaa; Laura Gallegos; Frank A Gomez
Journal:  Micromachines (Basel)       Date:  2019-09-15       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.