| Literature DB >> 29713526 |
Jeroen van Rooij1, Angela Engel2, Lies Remeijer1, Hugo van Cleijnenbreugel3, René Wubbels2.
Abstract
PURPOSE: To investigate the long-term anatomical and functional outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK).Entities:
Year: 2018 PMID: 29713526 PMCID: PMC5866901 DOI: 10.1155/2018/7320816
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Demographic data—on a per eye basis—at baseline; the number of patients was 95.
| Gender | |
| Male | 56 (49%) |
| Female | 58 (51%) |
| Eye | |
| Right | 62 (54%) |
| Left | 52 (46%) |
| Age at surgery | 69.0 ± 7.9 |
| Indication for DSAEK | |
| FED | 108 (95%) |
| PBK | 4 (4%) |
| Decompensation/primary graft failure | 2 (2%) |
DSAEK: Descemet stripping automated endothelial keratoplasty; FED: Fuchs' endothelial dystrophy; PBK: pseudophakic bullous keratopathy.
Ophthalmic and anatomical outcomes (means ± SD) and the number of eyes (n) that were assessed at baseline and during follow-up.
| Baseline | 1 month | 3 months | 6 months | 1 year | 2 years | 3 years | 5 years | 7 years | |
|---|---|---|---|---|---|---|---|---|---|
| BSCVA (logMAR) | 0.48 ± 0.27 | 0.33 ± 0.18 | 0.26 ± 0.17 | 0.21 ± 0.13 | 0.18 ± 0.13 | 0.17 ± 0.16 | 0.15 ± 0.14 | 0.19 ± 0.26 | 0.18 ± 0.20 |
| Straylight (log(s)) | 1.53 ± 0.22 | 1.40 ± 0.24 | 1.44 ± 0.24 | 1.40 ± 0.17 | 1.41 ± 0.15 | 1.38 ± 0.25 | 1.43 ± 0.17 | 1.44 ± 0.21 | 1.45 ± 0.19 |
| Graft ECD (cells/mm2) | 2736 ± 153 | 1837 ± 567 | 1929 ± 583 | 1864 ± 521 | 1783 ± 609 | 1672 ± 552 | 1501 ± 607 | 1237 ± 524 | 1058 ± 587 |
| Corneal thickness ( | 683 ± 95 | 595 ± 50 | 592 ± 50 | 592 ± 47 | 589 ± 46 | 588 ± 46 | 587 ± 48 | 610 ± 87 | 617 ± 58 |
SD: standard deviation; BSCVA: best spectacle corrected visual acuity; ECD: endothelial cell density. aIn parentheses, the number of eyes for which straylight measurements were attempted.
Figure 1Mean best spectacle-corrected visual acuity (BSCVA) at baseline and during follow-up. Error bars represent the 95% CI.
Figure 2Mean endothelial cell density (ECD) at baseline and during follow-up. Error bars represent the 95% CI.