Literature DB >> 29710741

The comparison of transfemoral amputees using mechanical and microprocessor- controlled prosthetic knee under different walking speeds: A randomized cross-over trial.

Wujing Cao1,2, Hongliu Yu1,2,3, Weiliang Zhao1,2, Qiaoling Meng1,2,3, Wenming Chen1,2.   

Abstract

BACKGROUND: The microprocessor-controlled prosthetic knees have been introduced to transfemoral amputees due to advances in biomedical engineering. A body of scientific literature has shown that the microprocessor-controlled prosthetic knees improve the gait and functional abilities of persons with transfemoral amputation.
OBJECTIVE: The aim of this study was to propose a new microprocessor-controlled prosthetic knee (MPK) and compare it with non-microprocessor-controlled prosthetic knees (NMPKs) under different walking speeds.
METHODS: The microprocessor-controlled prosthetic knee (i-KNEE) with hydraulic damper was developed. The comfortable self-selected walking speeds of 12 subjects with i-KNEE and NMPK were obtained. The maximum swing flexion knee angle and gait symmetry were compared in i-KNEE and NMPK condition.
RESULTS: The comfortable self-selected walking speeds of some subjects were higher with i-KNEE while some were not. There was no significant difference in comfortable self-selected walking speed between the i-KNEE and the NMPK condition (P= 0.138). The peak prosthetic knee flexion during swing in the i-KNEE condition was between sixty and seventy degree under any walking speed. In the NMPK condition, the maximum swing flexion knee angle changed significantly. And it increased with walking speed. There is no significant difference in knee kinematic symmetry when the subjects wear the i-KNEE or NMPK.
CONCLUSIONS: The results of this study indicated that the new microprocessor-controlled prosthetic knee was suitable for transfemoral amputees. The maximum swing flexion knee angle under different walking speeds showed different properties in the NMPK and i-KNEE condition. The i-KNEE was more adaptive to speed changes. There was little difference of comfortable self-selected walking speed between i-KNEE and NMPK condition.

Entities:  

Keywords:  Transfemoral amputees; gait symmetry; maximum swing flexion knee angle; microprocessor-controlled prosthetic knees

Mesh:

Year:  2018        PMID: 29710741     DOI: 10.3233/THC-171157

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  1 in total

1.  Effects of microprocessor-controlled prosthetic knees on self-reported mobility, quality of life, and psychological states in patients with transfemoral amputations.

Authors:  Ekin İlke Şen; Tuğba Aydın; Derya Buğdaycı; Fatma Nur Kesiktaş
Journal:  Acta Orthop Traumatol Turc       Date:  2020-09       Impact factor: 1.511

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.