Literature DB >> 29707362

How to recognize silent atrial fibrillation in pacemakers and defibrillators-the value of atrial electrograms.

Juan Benezet-Mazuecos1, Jose Manuel Rubio1, José Antonio Iglesias1, Juan José de la Vieja1.   

Abstract

Today's pacemakers and defibrillators include diagnostic tools for detecting and treating cardiac arrhythmias like silent atrial fibrillation as atrial high rate episodes (AHREs). This diagnostic capability is crucial to prevent the potential embolic complications this AHREs are related to. However, sometimes data retrieved from diagnostic counters may be misleading reflecting limitations of detection algorithms, which must follow mathematical rules to classify events on a beat-to-beat basis. The incorporation of stored electrograms has been an important milestone in improving the diagnostic capabilities of these devices confirming the arrhythmia diagnosis.

Entities:  

Keywords:  Pacemaker; atrial electrograms (EGMs); atrial high rate episodes (AHREs); defibrillator; silent atrial fibrillation (AF)

Year:  2018        PMID: 29707362      PMCID: PMC5906288          DOI: 10.21037/jtd.2018.03.38

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  5 in total

1.  An unusual cause of automatic mode switching in the absence of an atrial tachyarrhythmia.

Authors:  Mohammed Almehairi; Adrian Baranchuk; Amer Johri; Jane Caldwell
Journal:  Pacing Clin Electrophysiol       Date:  2013-11-11       Impact factor: 1.976

2.  Is the atrial high rate episode diagnostic feature reliable in detecting paroxysmal episodes of atrial tachyarrhythmias?

Authors:  K Seidl; E Meisel; E VanAgt; F Ottenhoff; M Hess; B Hauer; R Zahn; J Senges
Journal:  Pacing Clin Electrophysiol       Date:  1998-04       Impact factor: 1.976

Review 3.  Pacemaker stored electrograms: teaching us what is really going on in our patients.

Authors:  Bernd Nowak
Journal:  Pacing Clin Electrophysiol       Date:  2002-05       Impact factor: 1.976

4.  Clinical utility of intraatrial pacemaker stored electrograms to diagnose atrial fibrillation and flutter.

Authors:  W M Pollak; J D Simmons; A Interian; S A Atapattu; A Castellanos; R J Myerburg; R D Mitrani
Journal:  Pacing Clin Electrophysiol       Date:  2001-04       Impact factor: 1.976

Review 5.  Atrial high rate episodes in patients with dual-chamber cardiac implantable electronic devices: unmasking silent atrial fibrillation.

Authors:  Juan Benezet-Mazuecos; José Manuel Rubio; Jerónimo Farré
Journal:  Pacing Clin Electrophysiol       Date:  2014-05-30       Impact factor: 1.976

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.