Doppler color-flow imaging assessment of shunt size in atrial septal defect.

C Pollick1, H Sullivan, B Cujec, S Wilansky.   

Abstract

Two-dimensional echocardiography and pulsed-Doppler studies have not proved to be reliable methods of assessing left-to-right shunt size in atrial septal defect. Doppler color-flow imaging displays the transatrial jet, providing a new dimension with the potential capability of quantifying left-to-right shunt size. Twenty-three patients with atrial septal defect were studied by color-flow imaging and cardiac catheterization. The defect size measured by two-dimensional echocardiography, the maximal color-flow jet width in the atrial septum, and the maximal color-flow jet area in the right atrium were correlated with cardiac catheterization-derived left-to-right shunt size. Correlation coefficients were 0.57 (p less than 0.01), 0.67 (p less than 0.001), and 0.65 (p less than 0.01), respectively. Atrial septal color-flow jet width distinguished patients with less than a 2:1 left-to-right shunt size ratio (eight patients, jet width less than 15 mm in in all) from patients with greater than a 2:1 left-to-right shunt size ratio (15 patients, jet width greater than 15 mm in all). These results indicate that Doppler color-flow imaging can distinguish left-to-right shunt size in atrial septal defect accurately enough to influence decisions with regard to subsequent patient management.

Entities:  

Mesh:

Year:  1988        PMID: 2970335     DOI: 10.1161/01.cir.78.3.522

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Doppler echocardiographic evaluation of left ventricular diastolic function after surgical correction of atrial septal defect during childhood.

Authors:  T A Simmers; M Sobotka; E Rothuis; B J Delemarre
Journal:  Pediatr Cardiol       Date:  1994 Sep-Oct       Impact factor: 1.655

2.  Right to Left Ventricular Diameter Ratio ≥0.42 is the Warning Flag for Suspecting Atrial Septal Defect in Preschool Children: Age- and Body Surface Area-Related Reference Values Determined by M-Mode Echocardiography.

Authors:  Ikuo Hashimoto; Kazuhiro Watanabe; Fukiko Ichida
Journal:  Pediatr Cardiol       Date:  2015-12-24       Impact factor: 1.655

3.  Changes in blood volume shunting in patients with atrial septal defects: assessment of heart function with cardiovascular magnetic resonance during dobutamine stress.

Authors:  Sigurdur S Stephensen; Katarina Steding-Ehrenborg; Ulf Thilén; Johan Holm; Peter Hochbergs; Hakan Arheden; Marcus Carlsson
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2017-10-01       Impact factor: 6.875

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.